Danfoss EKC 319A User Manual

Danfoss EKC 319A User Manual

Temperature controller for limitation for the discharge gas temperature

Advertisement

User Guide
Temperature controller for limitation
for the discharge gas temperature
EKC 319A
ADAP-KOOL® Refrigeration control systems

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EKC 319A and is the answer not in the manual?

Questions and answers

Summary of Contents for Danfoss EKC 319A

  • Page 1 User Guide Temperature controller for limitation for the discharge gas temperature EKC 319A ADAP-KOOL® Refrigeration control systems...
  • Page 2 PC - either in situ or at a service company. EKC 319A Literature survey: Manual for EKC 319A ..............RS8EB.. Instructions for EKC 319A ............RI8HY.. Installation guide, "Data communication link for ADAP-KOOL® " ..............RC8AC..
  • Page 3 The address is sent to the gateway when the menu is set in pos. ON (The setting will automatically change back to Off after a few seconds.) Frequency 50 / 60 Hz Set the net frequency. (50=0, 60=1) EKC 319A Manual RS8EB102 © Danfoss 09-2005...
  • Page 4 (Status codes have lower priority than alarm codes. In other words, you cannot (0 = regulation) see a status code, if there is an active alarm). The individual status codes have the following meanings: S10: The regulation stopped by the internal or external start/ stop Manual RS8EB102 © Danfoss 09-2005 EKC 319A...
  • Page 5 5. Push both buttons again to conclude the setting Error messages The controller can give the following messages: Errors in the controller Error message The temperature sensor is disconnected The temperature sensor is shortcircuited Alarm message Alarm temperature limit is reached EKC 319A Manual RS8EB102 © Danfoss 09-2005...
  • Page 6 Data communication module 084B7093 EKA 175 (accessories), (RS 485 modul) Temperature sensor ...........Kindly refer to catalogue RK0YG AKV / AKVA Valves ..........Kindly refer to catalogue RK0YG EVRP valves ............Kindly refer to data sheet RD3KB Manual RS8EB102 © Danfoss 09-2005 EKC 319A...
  • Page 7: Data Communication

    • You will also be able to see • If you wish to check earlier the parameter names of the temperature measurements, functions on page 3-4. you can see them in the log collection. EKC 319A Manual RS8EB102 © Danfoss 09-2005...
  • Page 8 According to Local and currently valid legislation. Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alternations can be made without subsequential changes being necessary in specifications already agreed.

Table of Contents