Introduction

The Gas Safety (Installation and Use) Regulations 1998.
This appliance must be installed and serviced by a
competent person, in accordance with the above
regulations.
In the UK 'Corgi' Registered Installers (including the regions
of British Gas Services) undertake to work to a safe and
satisfactory standard.
Failure to install appliances correctly could lead to
prosecution.
It is in your own interest, and that of safety, to ensure that
the regulations are complied with.
Kingfisher Mf boilers are fully automatically controlled,
floor standing, fan powered, balanced or conventional
flued appliances using a cast iron heat exchanger and are
available in outputs ranging from 11.72 - 29.31 kW (40,000
- 100,000 Btu/h)
The boilers are designed for use on fully pumped open
vented or sealed water systems with an indirect hot water
cylinder or open vented gravity systems. THEY MUST
NOT BE CONNECTED TO A DIRECT CYLINDER.
The boilers are for use on Natural Gas (G20) only.
Samples of the Kingfisher Mf gas boilers have been
examined by Advantica Technologies Limited, a United
Kingdom Notified Body. The range is certified to comply
with the essential requirements of the Gas Appliance
Directive 90/396/EEC, the Low Voltage Directive 72/23/
EEC and shows compliance with the Electro Magnetic
Compatibility Directive 89/336/EEC, the Boiler Efficiency
Directive 92/42/EEC and are therefore permitted to carry
the CE Mark.
Delivery & Kits Available
RSL Model is delivered in two packages (1) the boiler with
fittings and (2) the flue assembly.
CFL Model is delivered in one package.
Various flue kits and other options for the Kingfisher Mf
range of boilers are shown on Pages 38 & 39.
This appliance has been certified for safety. It is therefore important that no external control device (e.g. flue
dampers, economisers, etc.) be directly connected to the appliance unless covered by these Installation &
Service Instructions or otherwise recommended in writing. Any direct connection of a control device not
approved by Potterton could invalidate the CE Certification and normal appliance warranty.
Publication No. 5102977
Health and Safety Information for the Installer
and Service Engineer
Under the Consumer Protection Act 1987 and Section 6
of the Health and Safety at Work Act 1974, we are required
to provide information on substances hazardous to health.
Small quantities of adhesives and sealants used in the
product are cured and present no known hazards.
The following substances are also present.
Insulation and Seals
Material - Man Made Mineral Fibre.
Description - Boards, Ropes, Gaskets.
Known Hazards - Some people can suffer reddening
and itching of the skin. Fibre entry into the eye will
cause foreign body irritation which can cause severe
irritation to people wearing contact lenses. Irritation to
respiratory tract.
Precautions - Dust goggles will protect eyes. People
with a history of skin complaints may be particularly
susceptible to irritation. High dust levels are only likely
to arise following harsh abrasion. In general, normal
handling and use will not present high risk, follow good
hygiene practices, wash hands before, touching eyes,
consuming food, drinking or using the toilet.
First Aid - Medical attention must be sought following
eye contact or prolonged reddening of the skin.

Codes of Practice

The boiler must be installed in accordance with: The Gas
Safety (Installation and Use) Regulations 1998 and the
current issue of:-
The Building Regulations, Building Standards (Scotland)
Regulations, Local Building Regulations, Model and local
Water Undertaking Bye-laws, IEE Wiring Regulations and
Health & Safety Document No. 635 "The Electricity at
Work Regulations 1989".
For Ireland install in accordance with I.S. 813 "Installation
of Gas Appliances".