ALARM FUNCTION

ALARM LIST Window

On the Location bar, type http://192.168.0.10 (or IP address set for WJ-NT104)/almindex.html, or click the ALARM LIST
button on the MAIN PAGE to display the ALARM LIST window. The window displays a list of alarm input dates, times and
channels. To display recorded alarm images, click the icon on the list.
q
w
q RETURN TO MAIN PAGE
Click to return to the MAIN PAGE window.
w ALARM LIST
Displays a list of alarm IDs, dates, times and channels
where alarm was generated. The list stores up to 100
alarms. An icon at the right end of the line indicates
that images have been recorded. Clicking the icon will
display the alarm images.
e Alarm image display
Alarm images are displayed in this space. The image
display size is specified in the MODE SETUP window.
(Images for which size 640 x 240 was selected, will be
fitted to the screen (640 x 480)).
r ALARM IMAGE CONTROL PANEL
For frame-by-frame display of alarm images in CON-
TINUOUS RECORDING mode. The control panel is not
displayed in SINGLE FRAME RECORDING mode.
37
t
y
u
t GO TO FIRST FRAME
To jump to the first of a series of alarm images
y FRAME AT ALARM EVENT
To jump to the first image after an alarm in CONTINU-
OUS RECORDING (BEFORE/AFTER ALARM) mode; to
jump to the first of alarm images in CONTINUOUS
RECORDING (AFTER ALARM) mode.
u GO TO LAST FRAME
To jump to the last of a series of alarm images
i PREVIOUS FRAME
To move one frame backward.
o NEXT FRAME
To move one frame forward.