3. Installation

Mixing the Live and Neutral connections will damage the alarm.
Ensure that the same colours are used throughout the
premises for Live, Neutral and Interconnect wires (if used).
Mains operated products should be installed by a qualified
electrician as per the requirements for Electrical Installations
published as IEE Wiring Regulations – BS7671 current edition.
Failure to install this unit correctly may expose the user to
shock or fire hazards.
This unit is not waterproof and must not be exposed to dripping
or splashing liquids.
Alternative Energy Sources (Wind, Solar, UPS, etc.).
This product is designed to be connected to a Pure or True
Sine Wave 230 Vac supply. If connecting to a power source
that utilises an inverter, e.g. PV solar panel or UPS, the Total
Harmonic Distortion (THD) must be less than 5%. If in doubt
check with manufacturer of the inverter.
Light Dimmer Circuits
This product must not be powered from a light dimmer circuit.