To test an individual Alarm press and hold the
test button until he horn sounds and the red
light flashes. This will ensure that the sensor,
electronics and sounder are working.
To test the RadioLINK system, press and hold
the test button on one of the Alarms. The blue
light on the side of the Ei168RC base will come
on solid for around 3.5 seconds. Continue to
hold the test button until all the Alarms in the
system are sounding. This will take between
20 to 45 seconds depending on the number
of Alarms in the system, e.g. a system with 12
Alarms will need a 45 second test. Release the
test button when the test is completed. The
local Alarm will stop sounding but you will hear
the other Alarms sounding in the distance and
then die out.
DO NOT TEST WITH FLAME (this can set fire to the Alarm and
damage the house)
We do not recommend testing with smoke or heat as the results can
WARNING
be misleading unless special apparatus is used.