ATTACH THE CABLE HOLDER AND CONNECTION HOLDER
‡ Attach Wire conduit to Cable Holder with Lock Nut.
The thread of the installed Wire Conduit should be
less than 3/8 in. (10 mm)
Cable Holder
Lock Nut
Less than 3/8 in.
(10 mm)
Connection Holder
Wire Conduit
3
SETTING UP THE INDOOR UNIT
Mounting the indoor unit
For right side piping
(1) Pass the pipes and the drain hose through the piping
hole.
(2) Hook the unit onto the mounting plate.
(3) Pull the connecting cable into the indoor unit.
(4) Push the unit and apply the bottom hooks to the
mounting plate's support.
(5)
in place.
For left side piping
(1) Reverse the positions of the drain hose and drain cap.
Refer to "Exchange the drain hose".
(2) Connect the pipes and wrap tape around the insulation
of the piping joints tightly not to become thick.
(3) Pass the pipes, connecting cable and the drain hose
through the piping hole.
(4) Hook the unit onto the mounting plate.
(5) Push the unit and apply the bottom hooks to the
mounting plate's support.
(6)
in place.
Notes:
‡ Bend the pipes carefully as not to damage them.
‡ Lay the drain hose below the pipes.
4
CONNECTING THE DRAIN HOSE
Connecting the drain hose
(1) Glue and Connect a drain hose.
(2) Tape over the connecting part.
ø16 mm
Drain hose
Checking drainage
(1) Open the open panel.
(2)
(3) Pour some water into the drain pan.
(4) Check the water drains smoothly.
Screw
(AY-XPC15PU, A3-XPC18PU, AY-XP24PU)
Fig.2
Notes:
‡ Be careful not to allow the drain hose to rise, form a trap or leave its end in water,
as shown below.
‡ Coil thermal insulation around a drain hose extension, if running in the room.
(AY-XPC07PU, AYXPC09PU, AY-XPC12PU)
Fig.3
MOUNTING PLATE
Taping
Hook
MOUNTING PLATE
Drain Hose
Drain Cap
Pipes
Drain Hose
Tape
Piping holder
(Only for AY-XPC15/18PU
AY-XP24PU)
Connecting cable
Piping holder
Pipes
Drain hose
No trap
allowed.
Not running wavy.
5 – 3
AY-XPC15PU
Screw
Fig.4
Piping route
zone without leaving any sharp edge.
Plate
Cut the plate along
Plate
Plate
notch.
Plate
Exchange the drain hose
(1) Remove the screw
Screw
and pull out the
drain hose.
(2) Pull out the drain
cap.
(3) Reconnect the drain hose to the right and
insert the drain cap to the left.
the screw removed in (1).
‡ Insert a hexagon wrench (4 mm diagonal) into
the drain cap, and press it fully.
Screw
Hexagon wrench
Drain Hose
Drain cap
Caution:
After replacing, make sure that both the drain
Not to rise.
No trap allowed.
Not left in water.
Drain Hose
Drain Cap