The fryer flue opening must not be placed close to the intake of the exhaust fan, and the fryer must
never have its flue extended in a "chimney" fashion. An extended flue changes the combustion
characteristics of the fryer, causing longer recovery time. It also frequently causes delayed ignition.
To provide the airflow necessary for good combustion, the areas surrounding the fryer front, sides,
and rear must be kept unobstructed.
DANGER
This appliance must be installed with sufficient ventilation to prevent the occurrence
of unacceptable concentrations of substances harmful to the health of personnel in
the room in which it is installed.
Fryers must be installed in an area with an adequate air supply and adequate ventilation. Adequate
distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation
filter bank. Filters should be installed at an angle of 45º. Place a drip tray beneath the lowest edge
of the filter. For U.S. installation, NFPA standard No. 96 states, "A minimum distance of 18 in.
(450 mm) should be maintained between the flue outlet and the lower edge of the grease filter."
Frymaster recommends that the minimum distance be 24 in. (600 mm) from the flue outlet to the
bottom edge of the filter.
Information on construction and installation of ventilating hoods can be found in the NFPA standard
cited above. A copy of the standard may be obtained from the National Fire Protection Association,
Battery March Park, Quincy, MA 02269.
NATIONAL CODE REQUIREMENTS
The fryer's gas type is on the data plate inside the fryer door. Connect a fryer marked "NAT" only
to natural gas, those marked "PRO" only to propane gas, and those marked "MFG" only to
manufactured gas.
Installations in the UNITED STATES must conform to the latest edition of the National Fuel Gas
Code, ANSI Z223.1. In CANADA, installation must conform to the latest edition of Standard CAN-
/GCA-B149.1 or .2, "Installation Codes for Gas Burning Appliances & Equipment". In addition to
the applicable national code or standard, installation must also be in accordance with any local codes
for the area in which the equipment is installed.
In AUSTRALIA, this appliance must be installed by an authorized person, in accordance with the
manufacture's instructions, local gas regulations, and in accordance with AS 5601 / AG 601, local
authority, gas, electricity, and any other relevant statutory regulations.
Installation must be made with a gas connector that complies with national and local codes. In the
UNITED STATES, the applicable code is ANSI Z21.69 with Addenda, "Standard for Connectors
for Movable Gas Appliances". Quick-Disconnect devices, if used, must comply with national and
local codes. In the UNITED STATES, the code is ANSI Z21.41, "Standard for Quick-Disconnect
Devices for Use with Gas Fuel".
SOUTH AFRICA REQUIREMENTS
IMPORTANT INFORMATION FOR THE USER
This appliance may only be installed by a registered SAQCC Gas installer. All registered installers
are issued with a card carrying their registration number. Ask to be shown the card before allowing
the installation work to commence and make a note of the Installer registration number. Upon
2-2