Rheem 96v series Installation Instructions Manual page 32

4 position condensing two-stage, communicating gas furnaces w/ecm blower
Table of Contents

Advertisement

3
3a - RELOCATE THE Ø .403" DRAIN PLUG IN THE COLLECTOR BOX.
3b - RELOCATE 1/4" VINYL CAP (YELLOW) ON COLLECTOR BOX VENT TAP.
3a
3b
5
INSTALL CONDENSATE TRAP
DISCARD
5b
HOSE A
DISCARD
NOTE: TO PREVENT DAMAGE TO THE TRAP, THE INSTALLER
MAY ELECT TO INSTALL IT DURING A LATER STEP. (AFTER
THE UNIT IS ROTATED)
5a - REMOVE METAL BRACKET AND THE Ø.403 DRAIN PLUG- DISCARD.
5b - REMOVE HOSE "A" - DISCARD
5c - INSTALL Ø .559" CONDENSATE DRAIN PLUG AND CONDENSATE
TRAP GASKET AS SHOWN.
5d - INSTALL CONDENSATE TRAP. MAKE SURE THE
CHANNEL AT THE LOCATION SHOWN IN THE "IMPORTANT
SECTION" ENGAGES THE EDGE OF THE JACKET AT THE
LOCATION SPECIFIED.
5e - SECURE USING (3) SCREWS.
32
5a
5c
INSTALL
5d
4
4a - REMOVE RECTANGLE FLUSH MOUNT PLUG FROM JACKET SIDE - DISCARD
4b - PRE-DRILL (3) Ø1/8" HOLES AS SHOWN FOR CONDENSATE TRAP
4c - INSTALL 2" PIPE GROMMET IN JACKET
4d - SLIDE AIR DIFFUSER INTO INTAKE COUPLING
AND INSTALL INTO JACKET AS SHOWN.
AIR DIFFUSER
INTAKE COUPLING AND NUT
INSTALL
4c
INSTALL
AIR DIFFUSER
4d
FULLY SEATED
DISCARD
4a
4b
DRILL (3)
Ø 1/8" HOLES
!! IMPORTANT !!
CONDENSATE TRAP
INFORMATION
THIS CHANNEL
MUST ENGAGE
JACKET AT THIS
EDGE TO AVOID
AIR LEAKS TO
THE BURNER
VESTIBULE!
ST-A1194-33-02