Rheem 96v series Installation Instructions Manual page 24

4 position condensing two-stage, communicating gas furnaces w/ecm blower
Table of Contents

Advertisement

3
INSTALL HOSE E ON COLLECTOR BOX AS SHOWN.
INSTALL HOSE E ON COLLECTOR BOX AS SHOWN.
LET THE OPEN END HANG FREE UNTIL STEP 11.
LET THE OPEN END HANG FREE UNTIL STEP 11.
NOTE:
USE SOAPY WATER TO FACILITATE EASY HOSE AND TUBE ASSEMBLY
USE SOAPY WATER TO FACILITATE EASY HOSE AND TUBE ASSEMBLY
USE SOAPY WATER TO FACILITATE EASY HOSE AND TUBE ASSEMBLY
5
ROTATE
UNIT
5a
5a - ROTATE UNIT 180°
5b - REMOVE KNOCKOUTS WITH HAMMER AND FLAT HEAD SCREWDRIVER.
5b - REMOVE KNOCKOUTS WITH HAMMER AND FLAT HEAD SCREWDRIVER.
5b - REMOVE KNOCKOUTS WITH HAMMER AND FLAT HEAD SCREWDRIVER.
5c - THE JUNCTION BOX WILL HAVE TO BE RELOCATED FOR FLUE PIPE INSTALLATION.
5c - THE JUNCTION BOX WILL HAVE TO BE RELOCATED FOR FLUE PIPE INSTALLATION.
5c - THE JUNCTION BOX WILL HAVE TO BE RELOCATED FOR FLUE PIPE INSTALLATION.
SEE ELECTRICAL WIRING SECTION FOR INSTRUCTIONS.
SEE ELECTRICAL WIRING SECTION FOR INSTRUCTIONS.
5d - RE-DRILL (2) Ø1/8" HOLES IN BLOWER SHELF AS SHOWN FOR FLUE PIPE ASSEMBLY.
5d - RE-DRILL (2) Ø1/8" HOLES IN BLOWER SHELF AS SHOWN FOR FLUE PIPE ASSEMBLY.
5d - RE-DRILL (2) Ø1/8" HOLES IN BLOWER SHELF AS SHOWN FOR FLUE PIPE ASSEMBLY.
5e - PRE-DRILL (2) Ø3/16" HOLES IN JACKET AS SHOWN FOR CONDENSATE TRAP BRACKET.
5e - PRE-DRILL (2) Ø3/16" HOLES IN JACKET AS SHOWN FOR CONDENSATE TRAP BRACKET.
5e - PRE-DRILL (2) Ø3/16" HOLES IN JACKET AS SHOWN FOR CONDENSATE TRAP BRACKET.
6
DIFFUSER
FULLY SEATED
FULLY SEATED
INSTALL INTAKE COUPLING IN BLOWER
INSTALL INTAKE COUPLING IN BLOWER
SHELF HOLE AS SHOWN.
INSERT AIR DIFFUSER INTO COUPLING
INSERT AIR DIFFUSER INTO COUPLING
UNTIL TABS ARE SEATED.
24
4
4a
4a - RE-INSTALL ELBOW AND COUPLINGS (REMOVED IN STEP 1) IN THE
4a - RE-INSTALL ELBOW AND COUPLINGS (REMOVED IN STEP 1) IN THE
4a - RE-INSTALL ELBOW AND COUPLINGS (REMOVED IN STEP 1) IN THE
ORIENTATION AS SHOWN.
ORIENTATION AS SHOWN.
4b - RELOCATE 1/2" VINYL CAP (YELLOW) ON INDUCER COUPLING TO
4b - RELOCATE 1/2" VINYL CAP (YELLOW) ON INDUCER COUPLING TO
4b - RELOCATE 1/2" VINYL CAP (YELLOW) ON INDUCER COUPLING TO
OPPOSITE SIDE.
NOTE: LEAVE COUPLING CLAMP CONNECTIONS LOOSE UNTIL STEP 11.
NOTE: LEAVE COUPLING CLAMP CONNECTIONS LOOSE UNTIL STEP 11.
NOTE: LEAVE COUPLING CLAMP CONNECTIONS LOOSE UNTIL STEP 11.
REMOVE KNOCKOUTS
REMOVE KNOCKOUTS
5b
RELOCATE JUNCTION BOX AND DOOR SWITCH
RELOCATE JUNCTION BOX AND DOOR SWITCH
RELOCATE JUNCTION BOX AND DOOR SWITCH
SEE ELECTRICAL WIRING SECTION
SEE ELECTRICAL WIRING SECTION
SEE ELECTRICAL WIRING SECTION
SEE ELECTRICAL WIRING SECTION
FOR INSTRUCTIONS
FOR INSTRUCTIONS
5c
5c
DRILL (2)
3/16" HOLES
5e
7
7b
.559
.559
DRAIN PLUG
DRAIN PLUG
7a - REMOVE THE SMALL MOUNTING BRACKET AND THE .403" DRAIN PLUG - DISCARD.
7a - REMOVE THE SMALL MOUNTING BRACKET AND THE .403" DRAIN PLUG - DISCARD.
7a - REMOVE THE SMALL MOUNTING BRACKET AND THE .403" DRAIN PLUG - DISCARD.
7b - INSTALL .559" DRAIN PLUG IN CONDENSATE TRAP.
7b - INSTALL .559" DRAIN PLUG IN CONDENSATE TRAP.
7c - INSTALL DOWN FLOW CONDENSATE TRAP BRACKET WITH (2) SCREWS AS SHOWN.
7c - INSTALL DOWN FLOW CONDENSATE TRAP BRACKET WITH (2) SCREWS AS SHOWN.
7c - INSTALL DOWN FLOW CONDENSATE TRAP BRACKET WITH (2) SCREWS AS SHOWN.
NOTE:
NOTE:
IF THE IDB COUPLING IS
IF THE IDB COUPLING IS
REMOVED, IT MUST BE
REMOVED, IT MUST BE
REPLACED IN THE PROPER
REPLACED IN THE PROPER
ORIENTATION. AN ARROW IS
ORIENTATION. AN ARROW IS
ORIENTATION. AN ARROW IS
ORIENTATION. AN ARROW IS
PRESENT ON THE COUPLING
PRESENT ON THE COUPLING
TO INDICATE THE DIREC-
TO INDICATE THE DIREC-
TION OF EXHAUST FLOW.
TION OF EXHAUST FLOW.
MAKE SURE THE ARROW
MAKE SURE THE ARROW
POINTS IN THE CORRECT
POINTS IN THE CORRECT
DIRECTION.
DIRECTION.
4b
DRILL (2)
1/8" HOLES
IN BLOWER
SHELF
5d
(X2)
DISCARD
7a
7c
7c
ST-A1194-31-04