PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED 2010 Audiovox Electronics Corporation. All rights reserved. BEFORE YOU BEGIN Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components or routing wires near hot surfaces Avoid mounting components or routing wires near...
Ignition 3 output, see the following diagram. Use an SPDT relay (not supplied). Accessory 2/3 output, see the following diagram. Use an SPDT relay (not supplied). 2010 Audiovox Electronics Corporation. All rights reserved. ILLUMINATED ENTRY OUTPUT ( - ) HORN OUTPUT ( - )
Page 6
BLUE/BLACK ActiveOutput Wire Jump To ORANGE Accessory Output Wire Wire From Control Module TACH INPUT 2010 Audiovox Electronics Corporation. All rights reserved. Ignition Switch X CUT VATS Control Module Accessory 2/3 Fused +12 Volt Battery Source BLUE/BLACK Active Output Wire...
Negative switching Parking Lights: Connect the WHITE/RED wire to a good chassis ground. Connect the WHITE wire to the parking light output wire. 2010 Audiovox Electronics Corporation. All rights reserved. HOOD PIN INPUT ( - ) BRAKE INPUT ( + )
This wire will supply a ( - ) 500mA pulse both upon arming the system and upon successful completion of the remote start activation sequence and is typically used to re-lock the vehicle’s doors upon remote start if necessary. 2010 Audiovox Electronics Corporation. All rights reserved. BATTERY 12V ( + ) IGNITION 1 ( + )
B attery S ource B LAC K /Y E LLOW P uls e During C rank W ire To Vehicle's 2nd S tarter W ire UNLOCK ( - ) LOCK ( - ) 2010 Audiovox Electronics Corporation. All rights reserved.
Page 11
Verification: These wires will register positive voltage when the Lock and Unlock switches are activated. Connect the GREEN and BLUE wires shown in the diagram below. Positive Locks: Lock Unlock 2010 Audiovox Electronics Corporation. All rights reserved. Negative Locks: GREEN (-) Lock Output Lock Unlock BLUE (-) Unlock Output...
Page 12
Fused +12 Volt Battery Souce BLUE (-) Unlock Output Ground Fused +12 Volt Battery Source Resistor 2010 Audiovox Electronics Corporation. All rights reserved. To Door Lock Motor To Door Lock Motor BLUE (-) Unlock Output Vehicle Door Lock Control Relays...
Page 13
After installing aftermarket actuators, (not supplied). Connect the GREEN and BLUE wires shown in the diagram below using (2) SPDT relays (not supplied). Door Lock Actuator 2010 Audiovox Electronics Corporation. All rights reserved. Fused +12 Volt Battery Source Resistor Fused +12 Volt...
This 4 pin port is used for Code Alarm Car Link or Vehicle Tracking accessories. Brake Safety Shut Down Diesel Glow Plug Input Passlock / Passkey Interface (GM Only) Transponder Interface Activation Manual Arm / Disarm Inputs (factory keyless controls system) 2010 Audiovox Electronics Corporation. All rights reserved.
NOTE: The system will remain in feature programming mode as long as the ignition is on, there is no time limit. To exit programming turn the IGNITION OFF. 2010 Audiovox Electronics Corporation. All rights reserved. button to scroll through the selections in each feature button to change the desired feature.
Within the 7 flash time period, press and hold the The system will chirp 1 time indicating the system is now in tachless mode. 2010 Audiovox Electronics Corporation. All rights reserved. button.
Factory Disarm - Single 1 second pulse with unlock and remote start activation. 2nd Unlock - Same output as unlock with 2nd press of unlock. Start Status - Continuous ( - ) output during the remote start cycle. 2010 Audiovox Electronics Corporation. All rights reserved.
Page 19
3 - Running Lights: Controls the WHITE parking light output wire during remote start. Steady - Parking lights constant during the remote start cycle. Flashing - Parking lights flash at a slow pace during the remote start cycle. 2010 Audiovox Electronics Corporation. All rights reserved. 30mS 40mS 50mS...
Page 20
45 Second Delay - Diesel engine, delays the starter output wire for 45 seconds after the ignition has been powered up by the remote start. 1.5 Seconds 2 Seconds 2010 Audiovox Electronics Corporation. All rights reserved. 4 Seconds...
Panic Remote Start Remote Start Shut Down Run Time Extention 2 / 3 Hour Start Daily Start Timer 2010 Audiovox Electronics Corporation. All rights reserved. Car Find / Unlock Start Panic Operation Method Press and Release Press and Release Push and Hold (3 Sec)
Ignition ON/OFF, Press and Hold Valet Button, Press Start 4 times Press Lock + Start Press and Hold button. SHUTDOWN ZONE Hood Input Brake Input Remote Start Valet Mode Tach not learned / Crank Average not learned 2010 Audiovox Electronics Corporation. All rights reserved.
5550SST 2010 Audiovox Electronics Corporation. All rights reserved.
Page 24
2. This device must accept any interference received, including any interference that may cause undesired operation. Warning! Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 2010 Audiovox Electronics Corporation. All rights reserved.