Radiforce RX350 Instructions For Use Manual

Hide thumbs Also See for RX350:

Advertisement

Color LCD monitor

Instructions for Use

Important:
Please read this "Instructions for Use", and Installation Manual (separate
volume) carefully to familiarize yourself with safe and effective usage.
Please retain this manual for future reference.
• For monitor adjustment and settings, refer to the Installation Manual.
• The latest "Instructions for Use" is available for download from our web
site: http://www.eizoglobal.com
Gebrauchsanweisung
Wichtig:
Bitte lesen Sie diese „Gebrauchsanweisung" und das separate
Installationshandbuch sorgfältig durch, um sich mit dem sicheren und
sachgemäßen Gebrauch des Produkts vertraut zu machen. Bewahren
Sie dieses Handbuch zum späteren Nachschlagen auf.
• Informationen zur Anpassung und zu den Einstellungen des Monitors
finden Sie im Installationshandbuch.
• „Gebrauchsanweisung" steht Ihnen auf unserer Website zum Download
zur Verfügung: http://www.eizoglobal.com
Notice d'instruction
Important:
Veuillez lire attentivement ce « Notice d'instruction » ainsi que le Manuel
d'installation (tome séparé) afin de vous familiariser avec ce produit et de
l'utiliser efficacement et en toute sécurité. Veuillez conserver ce manuel
pour référence ultérieure.
• Pour le réglage et les paramètres du moniteur, consultez le Manuel
d'installation.
• La dernière version du « Notice d'instruction » est à disposition pour
téléchargement sur notre site Web : http://www.eizoglobal.com
Инструкция по эксплуатации
Внимание:
Внимательно прочтите настоящую «Инструкцию по эксплуатации»
и «Руководство по установке» (отдельный документ), чтобы
ознакомиться с правилами безопасной и эффективной
эксплуатации.
• Настройка монитора и параметры настройки описаны в Руководстве
по установке.
• «Инструкцию по эксплуатации» в последней редакции можно
загрузить с нашего веб-сайта: http://www.eizoglobal.com
使用说明书
重要事项:
请仔细阅读本"使用说明书"和"安装手册"(单独卷),熟悉安全和高
效使用。请保留本手册,以备日后参考。
• 有关显示器的调节和设定,请参考安装手册。
• 最新 "使用说明书"可在我们的网站上下载: http://www.eizoglobal.com

Advertisement

Table of Contents
loading

Summary of Contents for Radiforce RX350

  • Page 1: Instructions For Use

    Color LCD monitor Instructions for Use Important: Please read this “Instructions for Use”, and Installation Manual (separate volume) carefully to familiarize yourself with safe and effective usage. Please retain this manual for future reference. • For monitor adjustment and settings, refer to the Installation Manual. •...
  • Page 2 Instructions for Use Color LCD monitor...
  • Page 3: Safety Symbols

    SAFETY SYMBOLS This manual and this product use the safety symbols below. They denote critical information. Please read them carefully. WARNING CAUTION Failure to abide by the information in a Failure to abide by the information in a WARNING may result in serious injury CAUTION may result in moderate injury and/or and can be life threatening.
  • Page 4: Important

    PRECAUTIONS ● IMPORTANT • This product has been adjusted specifically for use in the region to which it was originally shipped. If the product is used outside the region, it may not operate as specified in the specifications. • To personal safety and proper maintenance, please read carefully this section and the caution statements on the monitor.
  • Page 5 WARNING If the unit begins to emit smoke, smells like something is burning, or makes strange noises, discon- nect all power connections immediately and contact your EIZO representative for advice. Attempting to use a malfunctioning unit may result in fire, electric shock, or equipment damage. Do not open the cabinet or modify the unit.
  • Page 6 Use the correct voltage. • The unit is designed for use with a specific voltage only. Connection to another voltage than specified in this “Instructions for Use” may cause fire, electric shock, or equipment damage. Power supply: 100-240Vac 50/60Hz • Do not overload your power circuit, as this may result in fire or electric shock. Handle the power cord with care.
  • Page 7 CAUTION Handle with care when carrying the unit. Disconnect the power cord and cables when moving the unit. Moving the unit with the power cord or cables attached is dangerous and may result in injury. Carry or place the unit according to the correct specified methods. •...
  • Page 8: Notice For This Monitor

    Notice for this monitor Intended use This product is intended to be used in displaying and viewing digital images for review, analysis and diagnosis by trained medical practitioners. It does not support the display of mammography images for diagnosis. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. Attention •...
  • Page 9: To Use The Monitor Comfortably

    • The backlight of the LCD panel has a fixed lifetime. When the screen becomes dark or begins to flicker, please contact your local EIZO representative. • The screen may have defective pixels or a small number of light dots on the screen. This is due to the characteristics of the panel itself, and is not a malfunction of the product.
  • Page 10: Table Of Contents

    CONTENTS PRECAUTIONS ............3 ● IMPORTANT ........... 3 Notice for this monitor ......... 7 CONTENTS ............. 9 Chapter 1 Introduction ........10 1-1. Features ............10 1-2. Package Contents ........11 1-3. EIZO LCD Utility Disk........11 ● Disk contents and software overview ....11 ●...
  • Page 11: Chapter 1 Introduction

    Chapter 1 Introduction Thank you very much for choosing an EIZO color LCD monitor. 1-1. Features • 21.3 inches • Supports a resolution of 3M pixels (Portrait: 1536 × 2048 dots (H × V)) • Uses high-contrast panel (1500:1). Enables the display of sharp images. •...
  • Page 12: Package Contents

    1-2. Package Contents Check that all the following items are included in the packaging box. If any items are missing or damaged, contact your local EIZO representative. Note • Please keep the packaging box and materials for future movement or transport of the monitor. •...
  • Page 13: Controls And Functions

    1-4. Controls and Functions Approx. 30˚ Adjustment menu 9 10 1. Integrated Front Sensor Detects the movement of a person in front of the monitor. (Mobile) 2. Ambient Light Sensor Measures the environmental illumination. 3. Presence Sensor Detects the movement of a person in front of the monitor. 4.
  • Page 14: Chapter 2 Connection

    Chapter 2 Connection 2-1. Connecting Cables Attention • Check that the monitor and the PC are powered off. • When replacing the current monitor with this monitor, be sure to change the PC settings for resolution and vertical scan frequency to those that are available for this monitor. Refer to the compatible resolution table before connecting the PC.
  • Page 15: Connecting Multiple Pcs

    Connecting multiple PCs For information on how to switch the input signals, refer to the Setup manual (on the CD-ROM). Signal cable: DD300 Signal cable: PP300 Setting up a daisy-chain connection Attention • Visit the EIZO website for information about monitors and graphic boards that can be used for the daisy-chain connection: http://www.eizoglobal.com •...
  • Page 16: Making Use Of Usb (Universal Serial Bus)

    Plug the power cord into a power outlet and the power connector on the monitor. Connect the USB cable when using RadiCS LE or ScreenManager Pro for Medical. For information about the connection to the USB upstream port, refer to “2-2. Making Use of USB (Universal Serial Bus)”...
  • Page 17: Connection Procedure (Setup Of Usb Function)

    ● Connection procedure (Setup of USB function) 1. Connect the monitor first to a PC using the signal cable, and run the PC. 2. Connect the supplied USB cable between the USB downstream port of a USB compatible PC (or another USB hub) and the monitor’s USB upstream port.
  • Page 18: Chapter 3 Setting Up

    Chapter 3 Setting Up 3-1. Adjusting the Screen Height and Angle Hold left and right edge of the monitor with both hands, and adjust the screen height, tilt and swivel of the screen to the best condition for working. Attention •...
  • Page 19: Attaching Arm

    3-2. Attaching Arm An optional arm (or an optional stand) can be attached by removing the stand section. For supported optional arms (or optional stands), refer to the EIZO website: http://www.eizoglobal.com Attention • When attaching an arm or stand, follow the instructions of their User’s Manual. •...
  • Page 20: Chapter 4 Troubleshooting

    Chapter 4 Troubleshooting If a problem still remains after applying the suggested remedies, contact your local EIZO representative. Problem Possible cause and remedy 1. No picture • Check whether the power cord is connected properly. • Power indicator does not light. •...
  • Page 21: Chapter 5 Specifications

    Chapter 5 Specifications 5-1. Specifications List LCD Panel Type RX350 IPS (Anti-Glare) RX350-AR IPS (Anti-reflection) Backlight Size 54.1cm (21.3 inch) (54.1cm diagonal) Resolution 3M pixels (Portrait orientation: 1536 dots × 2048 lines (H × V)) Display Size (H x V) 324.8mm ×...
  • Page 22: Main Default Settings

    Transportation/ Temperature -20˚C to 60˚C (32˚F to 95˚F) Storage Humidity 10% to 90% R.H. (no condensation) Environmental Air pressure 200 hPa to 1060 hPa Requirements 5-2. Main Default Settings CAL Switch Mode: The factory default display setting is DICOM mode. Mode Brightness Temperature...
  • Page 23: Dimensions

    5-3. Dimensions Unit: mm 70 ° (13.8) (13.8) (267) 326.4 (127) (127) 4xM4 32.5 5-4. Accessories Calibration Kit EIZO “RadiCS UX1” Ver. 4.4.2 or later EIZO “RadiCS Version Up Kit” Ver. 4.4.2 or later Network QC Management Software EIZO “RadiNET Pro” Ver. 4.4.2 or later EIZO “RadiNET Pro Lite”...
  • Page 24: Chapter 6 Glossary

    Chapter 6 Glossary Daisy-chain connection A method of connecting two or more monitors to a PC in a daisy-chain. DDC (Display Data Channel) VESA provides the standardization for the interactive communication of the setting information, etc. between a PC and the monitor. DICOM (Digital Imaging and Communication in Medicine) The DICOM standard was developed by the American College of Radiology and the National Electrical Manufacturer’s Association of the USA.
  • Page 25 sRGB (Standard RGB) International standard for color reproduction and color space among peripheral devices (such as monitors, printers, digital cameras, scanners). As a form of simple color matching for the Internet, colors can be displayed using tones close to those of the transmission and reception devices. Temperature Color temperature is a method to measure the white color tone, generally indicated in degrees Kelvin.
  • Page 26: Appendix

    Firefox is a registered trademark of the Mozilla Foundation. Kensington and MicroSaver are registered trademarks of ACCO Brands Corporation. EIZO, the EIZO Logo, ColorEdge, DuraVision, FlexScan, FORIS, RadiCS, RadiForce, RadiNET, Raptor, and ScreenManager are registered trademarks of EIZO Corporation in Japan and other countries.
  • Page 27: License / Copyright

    License / Copyright A round gothic bold bit map font designed by Ricoh is used for the characters displayed on this product. Medical Standard • It shall be assured that the final system is in compliance to IEC60601-1-1 requirement. • Power supplied equipment can emit electromagnetic waves, that could influence, limit or result in malfunction of the monitor.
  • Page 28: Emc Information

    Guidance and manufacturer’s declaration - electromagnetic emissions The RadiForce series is intended for use in the electromagnetic environment specified below. The customer or the user of the RadiForce series should assure that it is used in such an environment. Emission test...
  • Page 29 To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the RadiForce series is used exceeds the applicable RF compliance level above, the RadiForce series should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the RadiForce series.
  • Page 30 The RadiForce series is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the RadiForce series can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the RadiForce series as recommended below, according to the maximum output power of the communications equipment.
  • Page 31: China Measures For Rohs Compliance In Chinarohs

    China Measures for RoHS Compliance in ChinaRoHS 关于电子信息产品污染控制标识 本标识根据「电子信息产品污染控制管理办法」 ,适用于在中华人民共和国销售的电子信息产品。标识中央的 数字为环保使用期限的年数。只要您遵守该产品相关的安全及使用注意事项,在自制造日起算的年限内,不会 产生对环境污染或人体及财产的影响。上述标识粘贴在机器背面。 • 有毒有害物质或元素的名称及含量 部件名称 有毒有害物质或元素 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr(VI) ) (PBB) (PBDE) 印刷电路板 × ○ ○ ○ ○ ○ 机箱 ○ ○ ○ ○...
  • Page 32: Fcc Declaration Of Conformity

    Trade name: EIZO Model: RadiForce RX350 is in conformity with Part 15 of the FCC Rules. Operation of this product is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 33: Recycling Information/Informationen Zum Thema Recycling

    Recycling Information/Informationen zum Thema Recycling/ Informations sur le recyclage/Информация относно рециклиране Recycling Information This product, when disposed of, is supposed to be collected and recycled according to your country’s legislation to reduce environmental burden. When you dispose of this product, please contact a distributor or an affi liate in your country.
  • Page 34 Πληροφορίες ανακύκλωσης Το προϊόν αυτό, όταν απορρίπτεται, πρέπει να συλλέγεται και να ανακυκλώνεται σύμφωνα με τη νομοθεσία της χώρας σας έτσι ώστε να μην επιβαρύνει το περιβάλλον. Για να απορρίψετε το προϊόν, επικοινωνήστε με έναν αντιπρόσωπο ή μια θυγατρική εταιρεία στη χώρα σας. Οι...
  • Page 35 Informace o recyklaci Při likvidaci produktu musí být produkt vyzvednut a recyklován podle zákonů příslušné země, aby nedocházelo k zatěžování životního prostředí. Zbavujete-li se produktu, kontaktujte distributora nebo pobočku ve své zemi. Kontaktní adresy jsou uvedeny na následující webové stránce společnosti EIZO. http://www.eizoglobal.com Ringlussevõtu alane teave Keskkonnakoormuse vähendamiseks tuleks kasutatud tooted kokku koguda ja võtta ringlusse vastavalt teie...
  • Page 36 Информация относно рециклиране При изхвърлянето на този продукт се предлага събирането и рециклирането му съобразно законите на вашата страна за да се намали замърсяването на околната среда. Когато искате да се освободите от този продукт, моля свържете се с търговския му представител или със съответните органи отговарящи за...
  • Page 37 Phone: +86 512 6252 0100 Fax: +86 512 6252 1508 Siemensallee 84, 76187 Karlsruhe, Germany Phone: +49 721 20321 0 Fax: +49 721 20321 471 http://www.eizoglobal.com 1st Edition-November, 2015 Printed in Japan. 00N0L935A1 Copyright © 2015 EIZO Corporation All rights reserved. (U.M-RX350-5)

Table of Contents