Setup menus (continued)
USER menu <TIME CODE>
No./Item
500
For selecting whether to output the
VITC signal at the positions selected
by setup menu items No. 501 (VITC
VITC BLANK
POS-1) and No. 502 (VITC POS-2).
0000 BLANK :
VITC signals are not output.
0001
VITC signals are output.
501
This sets the position where the VITC
signal is to be inserted.
VITC POS-1
(For AJ-SD255P)
0000
:
0006
:
0010
Notes:
• The same line as the one used for the
setup menu items No. 502 (VITC POS-
2) and No. 662 (UMID POS) setting
cannot be set.
• The default settings are not restored
even if the RESET button is pressed
while holding down the SEARCH button.
502
This sets the position where the VITC
signal is to be inserted.
VITC POS-2
(For AJ-SD255P)
0000
:
0008
:
0010
Notes:
• The same line as the one used for the
setup menu items No. 501 (VITC POS-
1) and No. 662 (UMID POS) setting
cannot be set.
• The default settings are not restored
even if the RESET button is pressed
while holding down the SEARCH button.
503
This selects the signal to be
regenerated when the time code
generator (TCG) in the REGEN mode.
TCG REGEN
0000 TC&UB :
Both the time code and user bit are
regenerated.
0001
Only the time code is regenerated.
0002
Only the user bit is regenerated.
The underlined items indicates the initial setting.
26
Description
THRU :
(For AJ-SD255E)
10L
0000
7L
:
:
:
16L
0004
11L
:
:
:
20L
0015
22L
(For AJ-SD255E)
10L
0000
7L
:
:
:
18L
0006
13L
:
:
:
20L
0015
22L
TC :
UB :
No./Item
505
This selects the time code to be used
when an external time code is to be
used.
EXT TC SEL
0000 LTC :
The LTC of the TIME CODE IN
connector is used.
0001 VITC :
The VITC of the input video signal or
the timecode of the IEEE1394 digital
input signal is used.
506
This sets the usage status of the user
bit of the time code generated by the
TCG.
BINARY GP
0000 000 :
NOT SPECIFIED (character set not
specified)
0001 001 :
ISO CHARACTER (8 bits character set
based on ISO646, ISO2022)
0002 010 : UNASSIGNED 1 (undefined)
0003 011 : UNASSIGNED 2 (undefined)
0004 100 : UNASSIGNED 3 (undefined)
0005 101 : PAGE/LINE
0006 110 : UNASSIGNED 4 (undefined)
0007 111 : UNASSIGNED 5 (undefined)
507
This selects whether to control the
phase correction of the LTC which is
output from the TIME CODE OUT
PHASE
connector.
CORR
0000 OFF :
Phase correction control is not
performed.
0001
ON :
Phase correction control is performed.
508
This selects whether the CF flag of the
TCG is to ON.
TCG CF
0000 OFF : CF flag is OFF.
FLAG
0001
ON : CF flag is ON.
509
This selects the DF or NDF mode for
CTL and TCG.
DF MODE
0000
DF :
(For AJ-SD255P)
The drop frame mode is used.
0001 NDF :
The non-drop frame mode is used.
Note:
DF/NDF switching is valid only when the
CONTROL switch is set to LOCAL or the
setup menu No. 001 (LOCAL ENA) is set
to ENA.
Description