Switching Logic (switch-selectable voltage)
LED
red
Switching Logic (non-switch selectable)
Alarm output - Fail-safe option
No
Fault
Fault
LED 2
LED 2
red
off

Maintenance

SITRANS LPS200 requires no maintenance or cleaning under normal operating
conditions. Under severe operating conditions, the measuring vane may require periodic
cleaning. Brush off any accumulated deposits, taking care not to bend the vane.
7ML19985FS62
SITRANS LPS200 – OPERATING INSTRUCTIONS
LED
green
Connection example
Full detector with fail-safe option.
Output signal signals a fault if level reaches
high level switching point, the main voltage
fails, there is a faulty connection, or if the
unit is faulty.
signal