Test condition
3, 4
Mode
ARI
"A" Cooling Steady State
at rated compressor Speed
"B-2" Cooling Steady State
at rated compressor Speed
SEER
"B-1" Cooling Steady State
(Cooling)
at minimum compressor Speed
Low ambient Cooling Steady State
at minimum compressor Speed
Intermediate Cooling Steady State
at Intermediate compressor Speed 5
Standard Rating-Heating
at rated compressor Speed
Low temperature Heating
at rated compressor Speed
Max temperature Heating
at minimum compressor Speed
HSPF
(Heating)
High temperature Heating
at minimum compressor Speed
Frost Accumulation
at rated compressor Speed
Frost Accumulation
at Intermediate compressor Speed 5
5: At Intermediate compressor Speed
=("Cooling rated compressor speed" - "minimum compressor speed") / 3 + "minimum compressor speed".
OPERATING RANGE
(1) POWER SUPPLY
Outdoor unit
(2) OPERATION
Mode
Condition
Standard temperature
Maximum temperature
Cooling
Minimum temperature
Maximum humidity
Standard temperature
Heating
Maximum temperature
Minimum temperature
Test
Rated voltage
208/230 V
Min. 187
1 phase
60 Hz
DB
80
90
67
70
80
70
Indoor air condition (°F)
Dry bulb
Wet bulb
80
80
80
80
80
70
70
70
70
70
70
Guaranteed voltage (V)
208
230
Max. 253
Intake air temperature (°F)
Indoor
WB
67
73
57
78%
60
67
60
5
Outdoor air condition (°F)
Dry bulb
67
95
67
82
67
82
67
67
67
87
60
47
60
17
60
62
60
47
60
35
60
35
Outdoor
DB
95
115
14
47
75
14
Wet bulb
(75)
(65)
(65)
(53.5)
(69)
43
15
56.5
43
33
33
WB
43
65
13

Hide quick links: