OPERATING PROCEDURE
4. Removing the nozzle assembly
(1) Remove the panel (Refer to 1.) and the corner box.
(2) Remove the indoor/outdoor connecting wire (Refer to
2 (2)-(7).).
(3) Remove the indoor electronic control P.C. board hold-
er.
(4) Pull out the drain hose from the nozzle assembly and
remove the nozzle assembly.
5. Removing the horizontal vane motor
(1) Remove the nozzle assembly. (Refer to 5.)
(2) Remove the screws of the horizontal vane motor unit.
(3) Disconnect the connector from the horizontal vane
motor.
(4) Remove the screws of the horizontal vane motor.
(5) Remove the horizontal vane motor from the horizontal
vane motor unit.
OBH548D
Photo 5
Screws of horizontal vane motor unit