Replacing A Midplane; Replacing An Sfp Module - IBM DS4700 Installation, User's, And Maintenance Manual

Express storage subsystem
Hide thumbs Also See for DS4700:
Table of Contents

Advertisement

Figure 117. Replacing an SFP module
10. Check the Bypass and Fault LEDs for the new SFP module.
11. Based on the status of the Bypass and Fault LEDs, choose one of the
12. Is the problem corrected?
13. Complete any remaining Recovery Guru procedures, if needed.
14. Use the DS4000 Storage Manager Subsystem Management window to check
15. Remove the antistatic protection.
16. Does any component have a Needs Attention status?
17. Use the DS4000 Storage Manager client software to print a new storage

Replacing a midplane

Attention:
"Handling static-sensitive devices" on page 33 when removing components.
Perform the following steps to replace a midplane:
178
IBM System Storage DS4700 Express Storage Subsystem: Installation, User's and Maintenance Guide
9. Reconnect the interface cable.
ESM Fault Light
ESM
Fiber-optic cable
(Host interface cable)
following steps:
v Bypass LED or Fault LED is on - Reinstall the SFP module and cables,
and verify that the SFP module and cables are securely connected. Use the
fibre channel loopback and the LC-LC connector to perform path diagnostics
to ensure that the FC cable is good and the SFP on the other end of the
fibre channel connection is working properly. When finished, go to step 12.
v Bypass LED and Fault LED are off - Go to step 12.
v Yes - Go to step 13.
v No - Contact IBM Support.
the status the status of all components in the storage subsystem.
v Yes - Select the Recovery Guru toolbar button in the Subsystem
Management window, and complete the recovery procedure. If the problem
persists, contact IBM Support.
v No - Go to step 17.
subsystem profile.
Observe handling static-sensitive device precautions stated in
SFP
Transceiver

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents