General - Keston Combi C30 Installation And Servicing Instructions

Hide thumbs Also See for Combi C30:
Table of Contents

Advertisement

Table 1 - General Data
Gas supply
Gas Supply Connection
Injector Size
Inlet Connection
Outlet Connection
Flow Connection
Return Connection
Flue Terminal Diameter
Average Flue Temp-Mass Flow Rate
Maximum Working Pressure (Sealed Systems)
Maximum Domestic Hot Water Inlet Pressure
Minimum Domestic Hot Water Inlet Pressure*
Minimum DHW Inlet Pressure to operate at 0.6
bar system pressure
Electrical Supply
Power Consumption
Fuse Rating
Water content
Packaged Weight
Maximum Installation Weight
Boiler Casing Size
*Required for maximum flow rate. Boiler operates down to 2 l/min DHW delivery
** In areas of low water pressure the DHW restrictor can be removed
Table 2 - Performance Data - Central Heating
Boiler Input :
Boiler Input 'Q'
Nett CV
Gross CV
Gas Consumption
Boiler Output :
Non Condensing 70
C Mean Water temp.
o
Condensing 40
C Mean Water temp.
o
Seasonal efficiency*
NOx Classification
* The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
Note. Gas consumption is calculated using a
calorific value of 38.7 MJ/m
or 34.9 MJ/m
(935 Btu/ft
) nett
3
3
To obtain the gas consumption at a different
calorific value:
a. For l/s - divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
b. For Btu/h - multiply the gross heat input (kW)
by 26.8
c. For ft
/h - divide the gross heat input (Btu/h)
3
by the gross C.V. of the gas (Btu/ft
d. For m
/h - multiply l/s by 3.6
3
8
SECTION 1 - GENERAL
bar (lb/in
bar (lb/in
bar (lb/in
CH
litre (gal)
DHW
litre (gal)
Height
Width
Depth
Max.
Min. 30
kW
24.3
6.1
kW
27.0
6.7
m
/h
2.512
0.623
3
(ft
/h)
(89)
(22)
3
kW
24.2
6.1
kW
25.6
6.4
SEDBUK 2005
91.1%
SEDBUK 2009
89.6%
CLASS 5
(1038 Btu/ft
) gross
3
3
)
3
)
3
30
mm
4.65
DHW
DHW
CH
CH
mm (in)
(DHW)
68
C - 13g/s
o
)
2
) (kPa)
2
1.3 (18.9) (130)
) (kPa)
2
bar
W
101
External : 3A
kg
34.40
kg
31.40
mm
mm
mm
Table 3 - Performance Data - Domestic Hot Water
Maximum DHW Input :
Min. 35
7.1
7.9
Gas Consumption
0.734
(25.9)
Maximum
DHW Flow Rate
7.1
at 35°C temp. rise.
7.5
DHW Specific Rate
91.1%
89.6%
Key to symbols
GB =
United Kingdom
PMS = Maximum operating pressure of water
= A room sealed appliance designed for connection via ducts to a
C13 C33 C53
horizontal or vertical terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside through
orifices which, in this case, are concentric. The fan is up stream of
the combustion chamber.
I
= An appliance designed for use on 2nd Family gas, Group H only.
2H
2H - G20 - 20mbar
15mm copper compression
15mm copper compression
15mm copper compression
22mm copper compression
22mm copper compression
50 (nominal)
2.5 (36.3)
10.0 (145) (1000)
1.3 (18.9)** (130)
0.5
230 V ~ 50 Hz.
Internal : T4A HRC L250 V
1.2 (0.26)
0.5 (0.11)
700
395
278
Nett CV
kW
Gross CV
kW
m
/h
3
(ft
/h)
3
kW
l/min
(gpm)
l/min
(gpm)
IE = Ireland
(Countries of destination)
Installation and Servicing
35
4.9
73ºC - 15g/s
114
34.50
31.50
30
35
30.4
35.4
33.7
39.3
3.135
3.658
(111)
(129)
30.3
35.3
12.4
14.5
(2.8)
(3.2)
14.5
16.9
(3.2)
(3.7)