Download Print this page

Controller Connection; Hdd Storage Calculation - HIKVISION DS-8100-S Series Installation Manual

Hide thumbs Also See for DS-8100-S Series:

Advertisement

Note:
The RS-485 PTZ control should be connected with
the T+ and T- pin on the RS-485 terminal block.

Controller Connection

To connect a controller to the DVR:
1. Disconnect pluggable block from the KB terminal block.
2. Unfasten stop screws from the KB D+, D- pluggable
block, insert signal cables into slots and fasten stop
screws. Ensure signal cables are in tight.
3. Connect Ta on controller to D+ on terminal block and Tb
on controller to D- on terminal block. Fasten stop screws.
4. Connect pluggable block back into terminal block.
Note:
Make sure both the controller and DVR are grounded.

HDD Storage Calculation

Chart
The following chart shows an estimation of storage space
used based on recording at one channel for an hour at a fixed
bit rate.
Bit Rate
96K
128K
160K
192K
224K
256K
4
Installation Guide - DS-8100-S Series DVR
Storage Used
42M
56M
70M
83M
98M
112M
320K
384K
448K
512K
640K
768K
896K
1024K
1280K
1536K
1792K
2048K
Note:
Please note that supplied values for storage space
used is just for reference. Storage space used is estimated by
formulas and may have some deviation from actual value.
140M
168M
196M
225M
281M
337M
393M
450M
562M
675M
787M
900M