4 ASCII protocol communication
Fig. 36: Protocol selection
4. Double-click the envelop icon in Protocol to configure the performance
parameters in it. The set communication parameters must match those of the
communication partner. Baud rate: 9600bps,Data bit: 8 bits,,Stop bit: 1 bit,
Parity: none, Character delay time:4ms,other parameters may use default data.
Fig. 37: Distributing parameters for ASCII protocol
5. As CP440 has only one type of RS422/485 interface, conversion equipment
shall be required if it has different interface from the communication partner, and all
other parameters shall be the same as CP340/341 when in ASCII communication.
CP340/CP341/CP440/CP441 Communication and Programming
Entry-ID: 88867653,
V1.0,
02/2014
22