Ruijie Networks reserves all copyrights of this document. Any reproduction, excerption, backup, modification, transmission, translation or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of Ruijie Networks is prohibited. are registered trademarks of Ruijie Networks.
It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it is assumed that the users are already familiar with the related terms and concepts. Obtaining Technical Assistance Ruijie Networks website: http://www.ruijienetworks.com/ Service Email: service_rj@ruijienetworks.com ...
· Chapter 1 Product Overview Ruijie MAP552(SR) is a Satellite AP for RG-AP520-I(G2), Featuring dual-band, dual-stream and delivering data rates of up to 1.167Gbps, MAP552(SR) supports concurrent 802.11b/g/n and 802.11a/n/ac and provides advanced functions such as dead zone compensation, position tracking and spectrum probe. Technical Specifications Table 1-1 Technical Specifications of RG-MAP552(SR) Model...
Page 5
· User Isolation Supported Radius Supported Whitelist Data Frame Static blacklist Filtering Dynamic blacklist Authentication PSK, Web, and 802.1x authentication Data Encryption WPA (TKIP), WPA2 (AES), WPA-PSK, and WEP (64 or 128 bits) Protection Supported Policy (CPP) Network Foundation Supported Protection Policy (NFPP) Management and Maintenance...
· Product Image Figure 1-1 Appearance of RG-MAP552(SR) The device is powered up via the RG-AP520-I(G2). Connect one end of the cable to the uplink port and the other end to the LAN2 port on RG-AP520-I(G2)., which is shown in the figure 1-2. Figure 1-2 AP520-I(G2) port ①...
Page 7
· State Frequency Meaning The AP is NOT receiving power. Or the AP is in Do Not Disturb mode, which can be disabled by software. Initialization in progress. Continuous blinking indicates faults. Blinking yellow 2.5Hz The AP is operational. Continuous The AP is operational with device virtual management (DVMG) 2.5Hz Blinking yellow...
· Chapter 2 Preparing for Installation To prevent device damage and bodily injury, please read carefully the safety recommendations described in this chapter. The recommendations do not cover all possible hazardous situations. Installation Safety Do not expose the AP to high temperature, dusts, or harmful gases. ...
· Maximum diameter (μm) Maximum concentration 1.4 x 10 7 x 10 2.4 x 10 1.3 x 10 (Particles/m Besides, the contents of salts, acids and sulfides in the air are also strictly limited for the equipment room. These substances can accelerate metal corrosion and the aging of some parts. Table 2-2 describes the limit of some hazardous gases such as SO S, NO and Cl...
Page 10
· Meter Multimeter The listed tools are customer supplied except wall anchors and screws.
· Chapter 3 Installing Access Point The RG-MAP552(SR) series must be fixed and installed indoors. Before installing the AP, make sure you have carefully read the requirements described in Chapter 2. Installation Flowchart Figure 3-1 Installation Flowchart Precautions To avoid damages to the AP, observe the following safety precautions: ...
· Keep away from high voltage cables. Install the device indoors. Do not expose the device in a thunderstorm or strong electric field. Keep the device clean and dust-free. Disconnect the device before cleaning it. ...
Page 13
· When mounting the AP on a wall, make sure the arrow on the mount kit points upward. The square feet should fit easily into the mounting slots. Do not forcibly push the AP into the slots. After installation, verify that the AP is securely fastened.
· Chapter 4 System Debugging Setting up a Debugging Environment RG-MAP552(SR) is powered up via RG-AP520-I(G2). Powering up the AP Checking before power-up Check if AP520-I(G2) and RG-MAP552(SR) are properly connected. Checking after power-up After powering up, it is recommended that you check the following to ensure normal operation of the AP. ...
· Chapter 5 Monitoring and Maintenance Monitoring You can observe the LED to monitor the AP in operation. Blinking yellow (2.5Hz): Initialization in progress. Continuous blinking indicates faults. Slow blinking green (On for 2s and Off for 2s, 0.25Hz): The AP is operational, and at least one STA is associated with the AP.
· Chapter 6 Troubleshooting Troubleshooting Flowchart Troubleshooting LED does not light up after the AP is powered on Verify that the cable is connected properly. LED keeps blinking yellow The AP is operational with DVMG state error. Wireless client cannot find the AP Follow the abovementioned two steps.
· Appendix A Connectors and Media 1000BASE-T/100BASE-TX/10BASE-T The 1000BASE-T/100BASE-TX/10BASE-T is a 10/100/1000 Mbps auto-negotiation port that supports auto MDI/MDIX. Compliant with IEEE 802.3ab, 1000BASE-T requires Category 5e 100-ohm UTP or STP (STP is recommended) with a maximum distance of 100 meters (328 feet). 1000BASE-T requires all four pairs of wires be connected for data transmission, as shown in Figure A-1.
Need help?
Do you have a question about the RG-MAP552(SR) series and is the answer not in the manual?