Function Settings - Ribao CS-311S Operation Manual

2+1 pockets coin sorter
Table of Contents

Advertisement

CS-311S Operation Manual V1.2
·Under main interface,press M+Key to save the quantity and amount
for genuine coins.It saves the accumulated data of the counting
results 。 Under main interface, when the counting quantity and
amount for genuine coins is 0, you can press M+ key to clear the
saved data.
Data Memory Read:
·Under main modes interface, press MR key to read stored data;
·Under self-learning interface, press M+ Key to read the original
self-learning data, this function is only available for maintenance
people.

9. Function Settings:

Press SET key to enter into Menu interface, shown as follows:
Directly press
and then press SET key to enter each into detailed operation
interface:
(1) BATCH
Enter into BATCH SET interface,press
channel.Under one channel, pressSET key,the BATCH will flash, at
this moment you can set the BATCH value through the numeric key
0 ~ 9(the upper limit is 9999) 。Press CLRkey you can clear the
BATCH setting.
MENU
> 1.BATCH
2.VALUE
3.SYSTEM
BATCH SET
CHANNEL:
1
BATCH:
0000
Page 10 of 17
4.TOTAL
5.TEST
6.LEARN
four keys to choose target submenu
VALUE:
2.00
key to switch the