Siemens simatic s7-400 FM 450-1 User Manual page 117

Counter module
Table of Contents

Advertisement

Status, interrupts, diagnostics
Status display
Interrupts
Hardware interrupt
Diagnostic interrupt
Diagnostics functions
Fault indication for internal and external faults
Reading diagnostics information
Data to the count signals and the digital inputs and outputs (applies to both counters)
Counter inputs 5 V (A , /A; B, /B; N, /N)
Level
Terminating resistor
Differential input voltage
Maximum count frequency
Electrical isolation toward S7-400 bus
Counter inputs 24 V (A*, B*, N*)
Low Level
High level
Input current
Minimum pulse width (maximum count frequency) ≥ 2.5 µs (200 kHz)
Digital inputs
Low Level
High level
Input current
Minimum pulse width (maximum input frequency)
Counter module FM 450-1
Manual, 02/2014, A5E03648739-02
Yes, 14 green LEDs for status of CR, DIR, inputs and outputs
Yes, configurable
Yes, configurable
Yes
Yes, 2 red LEDs
Yes
In compliance with RS 422
approx. 220 Ohms
Min. 0.5 V
500 kHz
No
- 30 ... + 5 V
+ 11 ... + 30 V
Typically 9 mA
≥ 25 µs (20 kHz)
(configurable)
- 28.8 ... + 5 V
+ 11 ... + 28.8 V
Typically 9 mA
≥ 2.5 µs (200 kHz)
≥ 25 µs (20 kHz)
(configurable)
Technical Data
12.2 Technical Data
117