Download Print this page

Specifications - Delta SMT130 Installation And Operating Instructions

Hide thumbs Also See for SMT130:

Advertisement

Single Models: SMT130, SMT150
1.
Single speed control mode: Turn the POWER switch
on to operate at single speed mode - the LED
indicator will be green.
Humidity Model: SMT130H
2.
Humidity control mode: Turn the POWER switch on to
operate at humidity control mode - the LED indicator
will be blue. When the ambient humidity is higher than
the user-adjustable set-point, the fan will run at full
speed. When the ambient humidity is lower than the
set-point, the fan will continue to run at the full speed
until a 10-minute time delay has elapsed, and then
will automatically change to the user-adjustable low
speed airflow.
3.
Full speed mode: Turn the MODE switch on to
operate at full speed mode - the LED indicator will be
amber.
Factory setting: low speed airflow 70CFM, humidity
60%RH.
Note: Humidity tolerance is about ±10%.
Motion Model: SMT130M
4.
Motion control mode: Turn the POWER switch on to
operate at motion control mode. When motion is
detected, the fan will run at full speed mode - the LED
indicator will be amber. When motion is not detected,
the fan will continue to run at the full speed until the
user-adjustable time delay has elapsed, and then will
automatically change to the user-adjustable low
speed airflow - the LED indicator will be green.
Factory setting: low speed airflow 70CFM, time delay 15
minutes.
Dual Speed Model: SMT150D
5.
Low speed control mode: Turn the POWER switch on
(MODE switch is off) to operate at the user-adjustable
low speed airflow - the LED will be green.
6.
Full speed control mode: Turn the POWER switch &
MODE switch on to operate at full speed mode - the
LED indicator will be amber. When the user turns the
MODE switch off, the fan will continue to run at the full
speed until the user-adjustable time delay has
elapsed, and then will automatically change to the
user-adjustable low speed airflow - the LED indicator
will be green.
Factory setting: low speed airflow 70CFM, time delay 15
minutes.
MAINTENANCE WARNING:
Disconnect the power source before working on the unit.
Routine maintenance must be done every year.
CAUTION:
1.
Never use gasoline, benzene, thinner or any other
such chemicals to clean the ventilating fan.
2.
Do not allow water to enter the motor.
Do not soak resin parts in water over 140°F (60°C).
3.
MODELS
SMT130/SMT130H/SMT130M/SMT150/SMT150D
CLEANING
1.
Pull down the springs to remove the grille.
2.
Wash and clean the grille. (Use non-abrasive kitchen
detergent and wipe dry with a new cloth.)
3.
Using a cloth dampened with non-abrasive kitchen
detergent, remove any dirt from the ventilating fan.
Wipe dry with a new cloth.
4.
Replace the grille.
DIMENSIONS
6"
(150)

SPECIFICATIONS

Voltage
Frequency
Model No.
(V)
(Hz)
SMT130
120
60
SMT130H
120
60
SMT130M
120
60
SMT150
120
60
SMT150D
120
60
Note: Design and specifications subject to change without notice.
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. ("Delta Electronics")
purchaser in the USA and Canada that the Breez ventilation fan products will be free
from defects in material or workmanship. This warranty is limited to three (3) years from
the original date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for any defective product will be supplied
free of charge for installation by the consumer. The warranty provided herein does not
cover charges for labor or other costs incurred in the troubleshooting, repair, removal,
and installation service.
2. All returns of defective parts or products must include the product model number, and
must be made through an authorized Delta Electronics distributor. Authorized returns
must be shipped prepaid. Repaired or replacement products will be shipped by Delta
Electronics F.O.B. shipping point.
3. Delta Electronics shall not be liable for any indirect, incidental, consequential,
punitive, or special damages arising out of or in connection with products use or
performance, regardless of the form of action whether in contract, tort (including
negligence), strict product liability or otherwise.
4. This warranty does not extend to fluorescent lamp starters and tubes.
5. The warranty does not cover if user does not comply with manufacturer's installation
manual.
6. To qualify for warranty service, you must notify Delta Electronics at the address or
telephone number below.
7. Delta Electronics shall have no liability to the original owner-user with respect to any
defect caused by abuse, misuse, neglect, improper transportation or storage,
improper testing, improper installation, improper operation, improper use, improper
maintenance, improper repair, improper alteration, improper modification, tampering
or accident of products or parts thereof, or unusual deterioration or degradation of
products or parts thereof due to a physical environment beyond the requirements of
products' speci cations.
Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889
Page 4.
7.675"
(195)
Unit: Inches(mm)
Power
Air Flow
Weight
Power
@ 0.1" SP
@ 0.1" SP
(lb.)
(W)
(W)
(CFM)
11.6
130
10.4
28
11.6
130
10.4
28
11.6
130
10.4
28
16.9
150
10.4
30
16.9
150
10.4
30
warrants to the original consumer
Note
Single
Speed
Humidity
Sensor
Motion
Sensor
Single
Speed
Dual
Speed

Advertisement

loading

This manual is also suitable for:

Smt130mSmt150Smt150dSmt130h