Installation
(The installation work must be performed by your dealer without fail.)

$Setting the cable compensation circuit

A maximum length of up to 3,280 feet (1,000 meters) is allowed for the cable between
each pan-tilt head and the multi-function controller (AW-RP605) (when BELDEN 8281
coaxial cables are used). However, if the cable length is to exceed 1,640 feet (500
meters), set the cable compensation circuit to ON by following the steps below.
(Factory setting: OFF)
1. Remove the four screws of the base connector panel, and pull the panel out toward
you.
2. Set the COMP switch on the COMP printed circuit board on the back side of the panel
to ON.
3. Return the panel to its original position, and secure it using the screws.
COMP switch
COMP printed circuit board