Louver Control; Louver Position; Air Direction Adjustment; Swing - Toshiba RAS-B16N3KV2-E1 Service Manual

Indoor unit/outdoor unit
Hide thumbs Also See for RAS-B16N3KV2-E1:
Table of Contents

Advertisement

Item

8. Louver control

This function controls the air direction of the indoor unit.
• The position is automatically controlled according to the operation
1) Louver
mode (COOL/HEAT).
position
• The set louver position is stored in memory by the microcomputer,
and the louver returns to the stored position when the next operation
is performed. (Cooling/Heating memory position)
The angle of the louver is indicated as the louver closes fully is 0°.
1) Louver position in cooling operation
2) Louver position in heating operation

2) Air direction adjustment

Horizontal
blowing

3) Swing

• Swing operation is performed in width 35° with the stop position as
the center.
• If the stop position exceeds either upper or lower limit position,
swing operation is performed in width 35° from the limit which the
stop position exceeded.
Operation flow and applicable data, etc.
Initial setting of "Cooling storage position"
Louver : Directs downward (40.9°)
Heating operation/
AUTO (HEAT)
Initial setting of "Heating storage position"
Louver : Directs downward (80.5˚)
Air direction
Inclined
Blowing
blowing
downward
Horizontal
Inclined
blowing
blowing
– 39–
FILE NO. SVM-15006
Description
• The louver position can
be arbitrarily set up by
pressing [FIX] button.
• Swing
When pressing
[SWING] button during
operation, the louver
starts swinging.