jablotron JA-60GSM Installation Manual
jablotron JA-60GSM Installation Manual

jablotron JA-60GSM Installation Manual

Dialer module
Hide thumbs Also See for JA-60GSM:

Advertisement

Quick Links

The JA-60GSM dialer is constructed for the JA-60, 63 and 65 alarm control panels. The dialer is used for communication via GSM. An
appropriate GSM provider is chosen according to the inserted SIM card. This Installation manual is intended for the JA-60GSM, version FJ61409.
The GSM module, when installed in the alarm control panel, enables:
Automatic sending of an event's text messages to up to 8 mobile phones
Dialing of programmed telephone numbers and playing of an audible warning signal
Data transfer to one or two Central Monitoring Stations (CMS)
Remote control and programming of the alarm system via SMS instruction messages from a mobile phone or from Jablotron's SMS
website
Remote control and programming of the alarm system using a telephone set keypad (mobile or land line)
Remote control of an appliance (heating system etc.) via telephone (mobile or land line)
Phone calls and convenient receiving and sending of SMS messages using an SMS-8010 telephone set (optional accessories; except
GSM kits e.g.JK-05) attached to the dialer module (via the GSM network)
Connection of the intercom SP-01 for communication with the premises
Internet connection using the GPRS data transfer
Programming of the alarm system via ComLink software
Programming and remote supervision of the alarm system via Jablotron's website www.gsmlink.cz
The
JA-60GSM
dialer
can
communicator's position in a JA-60, 63 or 65 control panel (either a
GSM module or a telephone line communicator module can be used in
a control panel – it is not possible to install both simultaneously).
a)
Disconnect the control panel's power supply (both AC and
backup battery). If the control panel has been previously used
before this installation, enter the programming mode before
disconnecting the power supply.
b)
We recommend you to disable the SIM card PIN code
protection before you insert it into the dialer. Use a mobile phone
to perform this task (if you have a NOKIA phone, select: Menu,
Settings, Security settings, PIN code request, Off). If you insist on
usage of the PIN, see section 5.1.
c)
Open the SIM card holder (by sliding it in the direction shown in
figure 1) and Insert the SIM card into the holder and close it by
sliding it back. – see figure 1.
d)
Attach the dialer into the control panel case and connect its flat
cable to the control panel's main board.
e)
Connect the GSM antenna (never switch the power supply on
without a proper antenna)
f)
Connect a SMS-8010 telephone set to the PHONE connector (or to
PHONE terminals) if desired. Only one telephone set can be attached
to the dialer. The PHONE output of the dialer should never be
connected to any other telephone network.
g)
If you use the AUX output to control an appliance, connect its
cable to the AUX output terminals (normally open dry contact,
max. 100mA / 60V) – see figure 1.
JA-60GSM dialer module
JA-60GSM dialer module
1
Installation of the dialer
be
installed
into
the
telephone
CAN CEL
MENU
N AMES
C ALLS
WRITE
R EAD
SPA C E
S M S
C A L L
1
3
2
M UT E
4
6
5
FLAS H
7
8
9
REDIAL
0
#
SP EAKER

Installation manual

Note: if your control panel supports programming of the PgX and
PgY outputs for the AUX function (sequences 238 and 239), the
appliance can also be controlled wirelessly from the control panel
by incorporating a UC-216 or UC-222 receiver module into the
system.
h)
Reconnect the control panel's power supply (backup battery
and AC). The system will show a P, (programming mode). The red
LED on the GSM dialer will light permanently (indicating that the
module is establishing a connection with the GSM network). The
LED will switch off after the connection is successfully
established.
If the LED starts flashing, the module was not able to connect to
the GSM network. In this case, switch off the control panel's power
completely. Remove the SIM card and insert it into a mobile phone
to confirm whether it is possible to connect to the network at this
location. You can also select a desired network manually if options
are available. Ensure that the SIM card does not request a PIN
code (optional use with a PIN code is described in section 5.1).
Once the SIM card works in the mobile phone, reinsert it into the
GSM dialer and repeat step h). If the GSM signal is weak in this
area, change the location of the GSM antenna before you try to
reestablish the connection.
i)
Attach the control panel's cover after the module has connected to
the GSM network (LED switched off).
j)
Enter 971 on the alarm system keypad (while in programming
mode) to monitor the GSM signal. The keypad will show a
number from 0 to 9 and it will sound a beep every second
indicating a new measurement. For proper functioning of the dialer
the signal strength should be 3 or higher. Find the best location for
the antenna while measuring the signal strength. To switch the
system back to programming mode press the N key.
k)
Without additional programming you can test the user features of
the dialer (phone calls from an attached phone, remote control of
the system via a remote phone, remote control of an appliance
etc.). See the following description.
l)
Set telephone numbers for automatic event reporting and the
other selectable features – see part 3.
m)
Programming of the GSM dialer is possible by entering
programming sequences via the alarm system's keypad (while in
programming mode). The most convenient programming method,
however is via a connected PC using Comlink software, or by
using the www.GSMlink.cz website.
figure 1
- 1 -
MFJ51212

Advertisement

Table of Contents
loading

Summary of Contents for jablotron JA-60GSM

  • Page 1: Installation Manual

    Installation manual The JA-60GSM dialer is constructed for the JA-60, 63 and 65 alarm control panels. The dialer is used for communication via GSM. An appropriate GSM provider is chosen according to the inserted SIM card. This Installation manual is intended for the JA-60GSM, version FJ61409.
  • Page 2: User Features Of The Gsm Dialer

    (F06060) then sequences 225 and 330 will be command performs the same action as the keys F 1 pushed on a executed and at the end programming mode will be exited (N). keypad. JA-60GSM dialer module - 2 - MFJ51212...
  • Page 3 2.10 JA-60GSM dialer module - 3 - MFJ51212...
  • Page 4: Sms And Audible Alarm Reports

    It is impossible to operate the system remotely without a valid numbers (see. 3.1). Procedure: remote access code (if used). From an authorized phone dial the JA-60GSM phone number.The SP-01 will ring once and then it will answer the 2.11...
  • Page 5: Customization Of Smss And Audible Reports

    Periodic test The x marks in the table show which events are assigned to which telephone numbers for SMS reporting. If you modify these, we recommend you to mark your settings in the table. JA-60GSM dialer module - 5 - MFJ51212...
  • Page 6 Wired detector #9 Wired detector #10 Wired detector #11 Wired detector #12 Wired detector #13 AUXON Wired detector #14 AUXOFF Wired detector #15 CREDIT Wired detector #16 PGON Wireless detector #1 PGOFF Wireless detector #2 JA-60GSM dialer module - 6 - MFJ51212...
  • Page 7: General Settings

    (this can be done with a mobile phone, see section 1). If you insist on using a PIN code, enter it after the GSM dialer has been powered up using: 70 xxxx F0 JA-60GSM communicator module - 7 - MFJ51212...
  • Page 8 N key. This sequence sets how the dialer will react to incoming calls. This setting is important for remote access by telephone. Note: The standard antenna supplied with the JA-60GSM has a gain of +3dB. 93 x where 5.10...
  • Page 9 5.14 Prepaid SIM cards The volume and sensitivity of the attached telephone can be adjusted The JA-60GSM communicator can send information about the credit balance of a prepaid SIM card. An SMS sent from any of the stored 974x receiver volume numbers (sequence 7t...) containing the word CREDIT followed by the...
  • Page 10: The Modem Function

    – they will not be sent after exiting 0 0 p 0 all reports to CMS p disabled programming mode 0 0 p 1 all reports to CMS p enabled JA-60GSM communicator module - 10 - MFJ51212...
  • Page 11: Technical Specifications

    Attached phone functionality • Telephone number for emergency calls Hereby, Jablotron Ltd., declares that this JA-60GSM is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Original of the conformity assessment can be found at the web page www.jablotron.cz, section Technical support.
  • Page 12: Brief List Of Programming Sequences

    08 y two independent CMS y=1 CMS2 is a back up for CMS1 Storing the event “data to CMS 09 y y=0 ... disable , y=1 ... enable Enable sent” into the event list JA-60GSM communicator module - 12 - MFJ51212...

Table of Contents