AG2
Series

Final Heater Assembly

Important! The combustion chamber & radiant tube sections must be installed in the following order.
20 Foot
30 Foot
40 Foot
50 Foot
Burner Control Box
w/16 in. Burner Tube
Expansion Joint on
Reflectors
Secured Joint on
Reflectors
Primary Combustion
Chamber with Clamp
NOTE: Refer to Page 3, Specifications Chart to identify specific models combustion chambers.
Stainless steel clamp on 150,000 BTU/h models (P/N: TP-220).
Stainless steel clamp on 150,000 BTU/h models (P/N: TP-220).
Key
23
3.0
Installation
NOTE: When securing joints on reflectors
which are rotated on an angle from horizontal,
secure joint only on top side of reflector to allow
for sufficient heater expansion and contraction.
Radiant Tube
Exchanger with Clamp
Baffle Location
Secure vent material to exchanger with three #8
sheet metal screws. Seal with high temperature
silicone sealant. Do not use tube clamp.