Brant Radiant Heaters AG2-20-65 Manual page 13

Gas-fired infrared agricultural tube heater ag2 series
Table of Contents

Advertisement

AG2
Series
Figure 3.2
Heater Mounting Layout
NOTE: A sticker identifying the
combustion chamber(s) is located on
the tube.
Suspension
Point
Burner Control Box
Suspension Points
16" Burner
Tube
Igniter/Sensor Box
Burner Control Box
Chart 3.2 •
Heater Mounting Requirements and Weights
20 ft.
21'-8" / 260"
30 ft.
31'-4" / 376"
40 ft.
41'-0" / 492"
50 ft.
50'-8" / 608"
* Refer to page 18 for U-bend configuration dimensions.
** Model requires 5EA-SUB accessory package when installing in a U-shaped configuration.
Suspension
Stainless Steel Tube Clamp
10 ft. Primary Combustion Chamber
NOTE: Type varies depending on
model, refer to the Specification
Chart.
3
2
120 lbs.
4
2
160 lbs.
5
2
190 lbs.
6
2
235 lbs.
13
3.0
Installation
Hanger Placement and Suspension
Point
Radiant Emitter Tube
Refer to the Specifications Chart.
(150 MBH models only)
145 lbs.
5
195 lbs.
6
235 lbs.
7
290 lbs.
8
Suspension Point
Radiant Emitter
Tube(s)
6
3
2
8
4
3**
8
5
3
10
6
4**

Advertisement