Main Supply
Voltage
Current type
Connected load
Protection (slow)
Type of protection
Protective class
Water connection
Max. feed temperature
Min. feed volume
Max. feed pressure
Performance data
Water flow rate
Operating pressure of water (using standard
nozzle)
Max. excess operating pressure (safety
valve)
Max. operating temperature of hot water
Switch-off temperature hot water
Operating temperature during continuous
operation with 59 °F/15 °C input temperature
Detergent suck in
Heating output
Max. recoil force of trigger gun
Nozzle size
Values determined as per EN 60355-2-79
Noise emission
Sound pressure level L
Uncertainty K
pA
Sound power level L
WA
Hand-arm vibration value
Hand spray gun
Spray lance
Uncertainty K
Fuel
Amount of oil
Oil grade
Dimensions and weights
Length x width x height
Typical operating weight
Detergent Tank
Total boiler capacity

Technical specifications

pA
+ Uncertainty K
WA
HDS-E 3.3/25-4M
Ec
V
460
Hz
3~ 60
kW
30
A
50
--
IPX5
--
I
°F (°C)
86 (30)
gpm (l/min)
4.4 (16.7)
psi (MPa)
87 (0.6)
gpm (l/min)
1.6-3.3 (6.1-12.3)
psi (MPa)
465-2520 (3.2-17.3) 465-2520 (3.2-17.3)
psi (MPa)
2972 (20.5)
°F (°C)
185 (85)
°F (°C)
208 (98)
°F (°C)
113 (45)
gpm (l/min)
0-0.13 (0-0.5)
kW
24
N
37.2
--
045
dB(A)
67
dB(A)
3
dB(A)
85
m/s
4.5
2
m/s
1.9
2
m/s
0.3
2
gal (l)
0.2 (0.75)
--
SAE 90
in (mm)
52.5 x 29.5 x 41.5
(1330 x 750 x 1060)
lbs (kg)
423 (192)
gal (l)
2.6+5.3 (10+20)
gal (l)
13.2 (50)
– 11
EN
HDS-E 3.3/25-4M
Ef
575
3~ 60
30
50
IPX5
I
86 (30)
4.4 (16.7)
87 (0.6)
1.6-3.3 (6.1-12.3)
2972 (20.5)
185 (85)
208 (98)
113 (45)
0-0.13 (0-0.5)
24
37.2
045
67
3
85
4.5
1.9
0.3
0.2 (0.75)
SAE 90
52.5 x 29.5 x 41.5
(1330 x 750 x 1060)
423 (192)
2.6+5.3 (10+20)
13.2 (50)