About the Boiler
This is a Wall Mounted Fan Assisted Balanced Flue Gas Boiler.
This boiler is for use with Natural Gas (G20) only at 20mbar and for use in GB & IE.
Your boiler is fully automatic in operation and requires very little attention apart from setting the
thermostat.
About Safety
The Gas Safety (Installation and Use) Regulations 1998.
This Appliance Must be installed and serviced by a Competent Person as stated in the above
Regulations.
If it is known or suspected that a fault exists on the appliance, it must not be used until the fault has
been corrected by a competent person.
If the appliance is installed in a compartment, do not use it for storage purposes. Do not obstruct any
purpose provided ventilation openings.
If a gas leak or fault is suspected turn off the appliance and consult your Local Gas Region or Service
Engineer.
Any warning labels on the appliance must be adhered to.
Consumer Notice: Please make sure you have carried out the simple checks detailed in these
instructions before asking for a Service Engineer to call, as a charge will be made for a service call
if it is not due to a manufacturing fault on the appliance.
The appliance should have the following minimum clearances for Safety and Maintenance, 15 mm at the
front (610 mm for servicing access), 5 mm each side, 50 mm at the bottom and 125 mm above the case.
Flammable materials must not be stored in close proximity to the boiler. Ensure that the flue terminal,
outside the house, does not become obstructed, particularly by foliage.
Potterton is a member of the Benchmark initiative and fully supports the aims of the programme.
Benchmark has been introduced to improve the standards of installation and commissioning of central
heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure
safety and efficiency.
The Benchmark Log Book is an important document and
must be kept safely with the boiler. Failure to install and
maintain this appliance in accordance with the
manufacturer's instructions may invalidate the warranty.
You should ensure that your installer/service engineer
completes the relevant sections of the log book when
appropriate.
Samples of the Suprima boilers have been examined by
Gastec, a United Kingdom Notified Body. The range is certified
to comply with the essential requirements of the Gas Appliance
Directive 90/396/EEC, the Low Voltage Directive 72/23/EEC
and shows compliance with the Electro Magnetic Compatibility
Directive 89/336/EEC,
EEC and are therefore permitted to carry the CE Mark.