OUTDOOR UNIT

2
* DSB-070LH/DSB-091LH/DSB-121LH(After)
1.Stop the air conditioner and disconnect the wire from Indoor Unit to
Outdoor Unit.
2. Disassemble the case. (Fig 1~2)
1 Remove the Top Panel. (Loosen thirteen screw)
2 Remove the Front Cabinet. (Loosen six screw)
3 Remove the Side Cabinet. (Loosen seven screw)
4 Remove the Guide Support. (Loosen two screw)
3. Removing the Propeller Fan. (Fig 3)
1 Loosen the Nut for fixing the Propeller Fan.
2 Remove the Plain Washer.
3 Remove the Propeller Fan.
4. Removing the Motor ODU. (Fig 4)
1 Loosen four screw at Bracket Motor.
2 Disconnect the wire at Control Panel and remove Motor ODU.
5. Removing the Dual Capacitor. (Fig 5)
1 Disconnect the wire at Control Panel.
2 Loosen a screw at Clamp Capacitor.
3 Remove the Dual Capacitor.
6. Removing the Over load Protector. (Fig 6~7)
1 Loosen a Hex Nut at Terminal Cover.
2 Remove the Terminal Cover.
3 Remove the wire at Over load Protector.
4 Remove the Over load Protector.