CLEAN STRAINER FILTER
• Stop the engine and close the water valve.
• Remove the filter cap.
• Remove the filter element, flush it thoroughly
with clean water or compressed air.
• Insert the cleaned filter element and screw on
the filter cap.
• Check the cap and the gasket for correct
seating and sealing.
• Open the water valve.
• Start the engine and check if there is water
leakage.
2.3 SEAWATER PUMP
• The internal diameter of hose connected to
seawater pump inlet should be Ø32.
• The cross section of the hose may shrink due to
inlet pressure drop. Therefore, the hose from
water pickup in the boat's hull to the seawater
pump inlet should be as short as possible and
must be made of steel wire reinforced material.
• The seawater pump impeller must be checked
periodically and replaced if necessary.
U125 Series Engines