3. ACCELERATION SENSOR AND CONTROL LEVER

When installing control lever cable to acceleration
sensor, be sure that the acceleration sensor lever
is fully released at the idle position and fully pulled
to the full-load position. The swing distance of the
lever between idle and full-load position is 60mm.
The procedures for control lever installation
1) Idle position setting
Make sure that the position value (%) indicates
0% in neutral condition.
2) Full load position setting
Make sure that the position value (%) indicates
full load range(90~99.2%) at fully forward lever
position. If not, disassemble and adjust the base
neutral position of the control lever by moving it
to the rear until the condition are met.
U125 Series Engines
YOU SHOULD PERFORM ABOVE PROCEDURES AFTER CONTROL
LEVER INSTALLATION WITH THE ENGINE NOT RUNNING BUT WITH
THE IGNITION KEY ON.
CAUTION
-29-
60 mm