TROUBLE SHOOTING

PROBLEM
Motor does not operate.
Machine circuit breaker trips
continuously.
Pad spins slowly or not at all.

SPECIFICATIONS

MODEL
WIDTH
HEIGHT
LENGTH
WEIGHT
DRIVE MOTOR
PAD/BRUSH SPEED
POWER CORD LENGTH
PAD DIAMETER
DECIBEL RATING AT
OPERATOR'S EAR, INDOORS ON TILE FLOOR
Castex BR- -1600 (06- -06)
CAUSE
Machine circuit breaker tripped.
(Spray buffing with the models is not
recommended).
Building circuit breaker tripped.
Faulty power cord.
Faulty wiring.
Faulty twist grip switch.
Faulty Rectifier.
Faulty Motor.
Soiled Pad.
Improper pad for application.
Defective circuit breaker.
Worn carbon brushes in motor.
Loose drive belt.
Broken drive belt.
Home
Find... Go To..
SOLUTION
Determine cause and reset breaker on
machine. Wait 15 seconds before
restarting machine.
Reset breaker and change to different
circuit.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Replace Pad.
Change to proper pad.
Contact Service Center.
Contact Service Center.
Tighten drive belt.
Replace drive belt.
BR- -1600
20.75 in / 530 mm
49 in / 1,240 mm
29.75 in / 760mm
68 lb / 31 kg
120 V, 1.5 hp, 15 A, 60 H
Z
2,000 rpm
75 ft / 23 m Gauge 3 X 1.5 mm
20 in / 510 mm
70 dBA