AirStage ASUA7RLAV Operating Manual

Indoor unit (wall mounted type)
Hide thumbs Also See for ASUA7RLAV:

Advertisement

OPERATING MANUAL

INDOOR UNIT (Wall mounted type)
Keep this operation manual for future reference
MODE D'EMPLOI
APPAREIL INTÉRIEUR (Type montage mural)
Conservez ce manuel pour toute référence ultérieure.
MANUAL DE FUNCIONAMIENTO
ASUA7RLAV
ASUA9RLAV
UNIDAD DE INTERIOR (Tipo montado en pared)
Conserve este manual para futura referencia.
ASUA12RLAV
ASUA14RLAV
MANUAL DE INSTRUÇÕES
UNIDADE INTERIOR (Tipo montado na parede)
Guarde este manual para referência futura.
PART NO. 9377772060-02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASUA7RLAV and is the answer not in the manual?

Questions and answers

Summary of Contents for AirStage ASUA7RLAV

  • Page 1: Operating Manual

    Keep this operation manual for future reference MODE D’EMPLOI APPAREIL INTÉRIEUR (Type montage mural) Conservez ce manuel pour toute référence ultérieure. MANUAL DE FUNCIONAMIENTO ASUA7RLAV ASUA9RLAV UNIDAD DE INTERIOR (Tipo montado en pared) Conserve este manual para futura referencia. ASUA12RLAV ASUA14RLAV MANUAL DE INSTRUÇÕES...
  • Page 2: Table Of Contents

    OPERATING MANUAL ● Check the condition of the installation stand for damage. ● Operate only with air fi lters installed. PART NO. 9377772060-02 VRF system indoor unit (Wall mounted type) ● Do not drink the water drained from the air conditioner. ●...
  • Page 3: Manual Auto Operation

    FILTER Indicator Lamp (red): It lights on if the fi lter became dirty. Horizontal direction Clean the fi lter referring to "CLEANING AND CARE". It lights off when RESET button is pressed after cleaning. Right-Left Louvers Intake Grille Air Filter (10) Airfl...
  • Page 4: Temperature And Humidity Range

    Cleaning Temperature and humidity range (1) Cleaning the intake grill Remove dust with a vacuum cleaner, wash the grille with warm water, ● The temperature and humidity required for operating this product is as and then dry with a clean and soft cloth. shown in the following table.
  • Page 5: Troubleshooting

    TROUBLESHOOTING The following conditions are not breakdowns or operation failures. Symptom Problem See page Doesn’t operate immediately: If the unit is stopped and then immediately started again, the compressor will not operate for about 3 — minutes, in order to prevent fuse blowouts. Whenever the electrical breaker is turned off then on again, the protection circuit will operate for —...
  • Page 6: Specifications

    The OPERATION indicator lamp (green) is fl ashing very fast. ● The wired remote controller or simple remote controller indicate Er (when connected). ● It has burning smell. SPECIFICATIONS MODEL ASUA7RLAV ASUA9RLAV ASUA12RLAV ASUA14RLAV POWER SOURCE 208/230 V ~ 60 Hz AVAILABLE VOLTAGE RANGE...