IDU name
The IDU name permanently appears in the prompt string of the Telnet/ASCII
terminal software, it can also be seen on the IDU LCD by pressing clear button while
in status display mode as well as on the Web browser window.
The name of the IDU can only be assigned using Telnet or ASCII terminal, this
cannot be done using IDU management interface.
The command line "Name <deviceName>" assigns a name to the IDU. The name
can be a maximum of 16 symbols long. If using space(s), the argument should be in
double quotes.
Example: Name "SAFterm2 14 7"
Security commands
For ASCII, Telnet and Web terminals only one user is supported. The default
username and password for Telnet terminal is:
Username: telnet
Password: saf
The default username and password for Web terminal is:
Username: SAF
Password: test
Take note of upper case and lower case type, it should be taken into account for
both username and password!
The passwords may contain spaces, if using space(s) the password should be
entered in quote marks.
For ASCII, Telnet and Web terminals the password can be changed simply re-
entering the appropriate security command while logged on. To log off press Ctrl+D,
the logging off is possible only if the password is specified. To disable password enter
the password command appropriate for the specific terminal type followed by empty
string, e.g., enable password "".
Important!
The specification of password (or username and password) should always be
followed by saving the configuration script (using "write" or "cfg write" commands)
otherwise the password request will be ignored after the restart of CPU.
The panel access code for the access from IDU panel can be specified from the
Telnet/ASCII console only. When the access code is specified the adjustment and
configuration of any IDU/ODU parameters and loopbacks from IDU LCD is not
available unless the correct access code is entered at the IDU (refer to "Setup" Mode
of the IDU LCD Management Interface). The specification of access code should also
be followed by saving the configuration script otherwise the access code value will be
set to zero (none) on the CPU restart. The panel access code can be changed simply
entering the new access code (number from 0 – 200) using panel access command.
In order to disable the panel access code, enter 0 value.
There is no default password set for ASCII terminal (ASCII console connected to
RS232 management port) nor the access code from IDU panel is specified, - it is set
to 0 (none).
Currently there are no possibilities to bypass password of any type of terminal, for
instance if the user has forgotten it. The boot recovery functionality for such cases
will be available in the upcoming software versions.
Modular Fast Ethernet Bridge Management System Technical Description and Configuration Guide
V. 3.12. 1.0 · © SAF Tehnika A/S 2003