RxLev= -66dBm
TxOut=Ok
TxPLL=Ok
RxPLL=Ok
t= 23C
Humidity=Low
Restart= 3
IDU t= 31C
LAN= Half Duplex
LAN link= OFF
LAN speed= 10M
RF Cable – OFF
MUX
0M+34M+0M+0M
RxAlarmLev =-71
UpTime=5371
DownTime=4
FrmErr=23
BBLoopback=OFF
Modular Fast Ethernet Bridge Management System Technical Description and Configuration Guide
Parameter RxLev indicates the level of the received signal,
values from –40 dBm to –90 dBm provide proper operation of
the system.
Parameter indicates operation status of ODU transmitter:
"Ok" indicates proper operation;
"Error" indicates internal fault in ODU transmitter, please
contact sales representative or manufacturer.
Parameter indicates operation status of ODU Tx Syntheser Loop
(PLL lock):
"Ok" indicates proper operation;
"Error" indicates internal fault in ODU transmitter, please
contact sales representative or manufacturer.
Parameter indicates operation status of ODU Rx Syntheser Loop
(PLL lock):
"Ok" indicates proper operation;
"Error" indicates internal fault in ODU receiver, please contact
sales representative or manufacturer.
Indicates ODU internal temperature
Parameter indicates humidity level inside ODU,
"Low" indicates acceptable moisture levels;
"High" indicates too high level of humidity, condensing.
Parameter indicates number of ODU management controller
restarts since counter was reset.
Parameter indicates internal temperature inside IDU
Parameter indicates the primary Ethernet port mode: "Eth=Half
Duplex" or "Eth= Full Duplex".
Indicates Ethernet LAN link integrity
Indicates the primary Ethernet port speed: 10M or 100M
Parameter indicates power consumption of the ODU:
"OK" indicates acceptable level;
"Short" indicates short circuit in cable;
"Off" indicates too low power consumption by ODU. This is most
likely due to the brake in the cable. If the cable is intact, the
ODU is faulty (contact your SAF Tehnika sales representative).
Indicates the current MUX slot speed configuration (see chapter
4.2.2 for details).
Indicates the Rx level (in dBm) at which the Radio Alarm is
switched on (parameter adjustable from Telnet/ASCII console).
Indicates the system up-time in seconds.
Indicates the system down-time (SL alarm on) in seconds.
Indicates the count of frames received from the WAN that has
error(s) within the time interval equal to the sum of uptime and
downtime counters.
Indicates if the base-band loopback is switched on or off.