SAF CFM-34-REBM Manual page 24

Cfm series
Table of Contents

Advertisement

rfTxOut
rfTxPLL
rfRxPLL
rfOduTemperature
rfOduHumidity
rfLoopback
rfRxAlarmLevel
brDescription
brVersion
brOperation
brLanMode
brLanSpeed
brLanLinkState
*m3Type
m3Description
m3Version
m3Speed
m3Operation
m3Rx
m3Tx
m3Loopback
Modular Fast Ethernet Bridge Management System Technical Description and Configuration Guide
Integer (32 bit)
error(0)
ok(1)
off(2)
Integer (32 bit)
error(0)
ok(1)
Integer (32 bit)
error(0)
ok(1)
Integer (32 bit)
Integer (32 bit)
low(0)
high(1)
Integer (32 bit)
off(0)
on(1)
Integer (32 bit)
String
String
Integer (32 bit)
none(0)
booting(1)
ok(2)
testing(3)
loopback(4)
illegalSpeed(5)
error(6)
Integer (32 bit)
other(0)
halfDuplex(1)
fullDuplex(2)
Integer (32 bit)
Integer (32 bit)
other(0)
linkOK(1)
linkLOS(2)
error(0)
e1(33)
v35(37)
bridge(43)
none(255)
String
String
Integer (32 bit)
Integer (32 bit)
none(0)
ok(2)
loopback(4)
illegalSpeed(5)
Integer (32 bit)
none(0)
ok(1)
noSignal(2)
noLink(3)
rxAIS(4)
Integer (32 bit)
none(0)
ok(1)
noSignal(2)
txAIS(4)
Integer (32 bit)
off(0)
on(1)
analog(2)
V. 3.12. 1.0 · © SAF Tehnika A/S 2003
Operation status of the ODU
transmitter:
ok – proper operation
error – internal fault (no data from
ODU)
off – Tx power = off
Operation status of ODU Tx
syntheser loop (PLL lock):
ok – normal operation
error - internal fault in ODU
transmitter
Operation status of ODU Rx
syntheser loop (PLL lock):
ok – normal operation
error - internal fault in ODU
transmitter
Internal temperature of ODU (
Humidity level inside ODU:
low - acceptable moisture level
RF loopback
Rx level (in dBm) at which the Radio
Alarm is switched on
Textual description of the Bridge
Textual version of the Bridge
Oprational status of the Bridge:
none – not initialized
testing, loopback, illegalOperation,
error – reserved
LAN duplex mode:
other – not initialized;
LAN speed
LAN link integrity:
other – not initialized;
Module type:
error – internal fault
none – no module installed or the
module does not support data
exchange with the management
controller (e.g., due to the software)
Description of the module
Textual version of the module
Module data transfer speed in kbps
Operational status of the module:
none – no data from the module
loopback – loopback is switched on
illegalSpeed – the speed
configuration of the MUX slot does
not mach the module speed
Rx statuss of the module:
none – not defined
noLink – for the REB module only
rxAIS – for the E1 module only
Tx statuss of the module:
none – not defined
noSignal – for V.35 module and REB
module (same as no link or LOS
alarm)
txAIS – for E1 module only (usually
switches on with the SL alarm)
Loopback in the module
0
C)
24