SAF CFM-34-REBM Manual page 23

Cfm series
Table of Contents

Advertisement

The following table describes all variables defined in the MIB.
Variable Name
termProduct
termDescription
termLocation
termVersion
termOperation
termIduTemperature
termRfCablePowerStatus
termUpTime
termDownTime
bbVersion
bbOperation
bbLinkCapacity
bbLinkCapacityDescription
bbLoopback
bridgeLanLinkLostAlarm
rfOperation
rfAlarm
rfVersion
rfSide
rfChannel
rfTxFrequency
rfRxFrequency
rfTxPower
rfRxState
rfRxLevel
rfCableAttenuation
Modular Fast Ethernet Bridge Management System Technical Description and Configuration Guide
Variable
Value List
Type
String
String
String
String
Integer (32 bit)
none(0)
booting(1)
ok(2)
testing(3)
error(4)
Integer (32 bit)
Integer (32 bit)
off(0)
ok(1)
short(2)
error(3)
Integer (32 bit)
Integer (32 bit)
String
Integer (32 bit)
none(0)
booting(1)
ok(2)
testing(3)
loopback(4)
illegalSpeed(5)
error(6)
Integer (32 bit)
String
Integer (32 bit)
off(0)
digital(1)
analog(2)
Integer (32 bit)
none(0)
on(1)
Integer (32 bit)
none(0)
booting(1)
ok(2)
testing(3)
error(4)
noDataFromODU
(5)
Integer (32 bit)
none(0)
on(1)
String
Integer (32 bit)
low(0)
high(1)
Integer (32 bit)
String
String
Integer (32 bit)
Integer (32 bit)
low(0)
ok(1)
error(2)
loopback(3)
Integer (32 bit)
Integer (32 bit)
V. 3.12. 1.0 · © SAF Tehnika A/S 2003
Description
Textual name of terminal type
Textual description of terminal
IDU name
Textual version of management
software
Terminal (IDU) operational status:
none – not initialized;
testing, illegalSpeed, error –
reserved
Temperature within IDU
(range: -128..127)
Indicates power consumption of the
ODU: ok - acceptable level,
short - short circuit in cable,
off - too low power consumption,
error – internal fault
System up-time in seconds
System down-time in seconds
Textual version of the Base-band
controller software
Operational status of the Base-band
modem:
none – not initialized
loopback – Base-band loop is set on
testing, illegalSpeed, error –
reserved
Base-band link capacity in Kbps
Comment on Base-band link
Base-band loopback
Link integrity on the Ethernet data
port (UTP),
none – normal operation
on – link lost
Operational status of the Radio:
none – not initialized
testing, error – reserved
noDataFromODU – no data is being
received from ODU
Radio Alarm, none – off
Textual version of the Radio
Band side of the Radio: low or high
Channel number
Tx frequency
Rx frequency
Transmitter power
Reception status:
low – Rx signal level
ok - normal
error - internal fault in the Radio
loopback – RF loop is set on
Received signal level [dBm]
Signal attenuation in ODU-IDU cable
(0...-20 db - proper operation)
23