Shutter Close Time Adj - Samsung PL120 Service Manual

Hide thumbs Also See for PL120:
Table of Contents

Advertisement

6. Adjustment

6.5. Shutter Close Time ADJ

NOTE
Adjust the Close timing of the device shutter by camera.
Because there is a deviation of shutter closing time by each set, make adjustments by each set to reduce this deviation.
AWB LOW item and AWB LOW are adjusted simultaneously.
<Adjustment method>
1) Prepare AE TESTER which is adjusted by LV 12.
2) Install AE TESTER on camera.
Brightness of the light box is 12 LV.
The color temperature of the light box is 3300K.
Figure 6.4
3) After inserting the microSD card containing the program file to the camera, turn on the power of the camera.
4) Refer to the specification (Illiminance) for testing.
a) Refer to the specification (Illiminance) for testing.
Line delay and Sub delay are adjusted so that the appropriate value can be identified to the specification
illuminance.
b) If the result line delay wis within the min and max range, it is OK. If it is outside of the range, process as NG.
c) Refer to the EEPROM WRITE information and write the adjustment result to EEPROM.
d) Refer to the CARD WRITE INFORMATION to write the adjustment result to the data file.
5) When the adjustment is completed, the camera will automatically be turned off.
<Adjustment result>
On the memory card, open and check if a CSV file was generated from the adjustment.
<Restriction>
If the capacity of CSV file is more than 30KB, clear all of the previous data and then, record
6-6
Copyright© 1995-2011 SAMSUNG. All rights reserved.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pl121