OBSERvED pROBLEM
Fireplace produces unwant-
ed odors
Fireplace shuts off in use
(ODS operates)
Gas odor even when control
knob is in OFF position
Gas odor during combustion
Dark residue on logs inside
of their fireplace Note: Af-
ter removing all causes of
residue deposits, completely
clean fireplace and appliance
off residue before reusing
appliance
28
TROUbLEShOOTING
Continued
pOSSIBLE CAUSE
1. Heater burning vapors from
paint, hair spray, glues,
cleaners, chemicals, new
carpet, etc. (See IMPOR-
TANT statement above)
2. Low fuel supply (propane/
LP only)
3. Gas leak. See Warning
statement at top of page
1. Not enough fresh air is
available
2. Low line pressure
3. O D S / p i l o t i s p a r t i a l l y
clogged
1. Gas leak. See Warning
statement at top of page
2. Control valve or gas control
defective
1. Foreign matter between
control valve and burner
2. Gas leak. See Warning
statement at top of page
1. Improper log placement
2. Drafts or other air currents
affecting flame pattern
3. Air holes at burner inlet
blocked
4. B u r n e r f l a m e h o l e s
blocked
www.fmiproducts.com
REMEDY
1. Open window to venti-
late room. Stop using odor
causing products while
heater is running
2. Refill supply tank (propane/
LP only)
3. Locate and correct all leaks
(see Checking Gas Con-
nections, page 15)
1. Open window and/or door
for ventilation
2. Contact local natural or
propane/LP gas company
3. C l e a n O D S / p i l o t ( s e e
Cleaning and Maintenance,
page 24)
1. Locate and correct all leaks
(see Checking Gas Con-
nections, page 15)
2. Replace control valve or
gas control
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Con-
nections, page 15)
1. Properly locate logs (see
Installing Logs, page 17)
2. Eliminate source of drafts
around heater
3. Clean out air holes at burner
inlet. Periodically repeat as
needed
4. Remove blockage
113109-01H