4. Press in and turn control knob clockwise
to the OFF position.
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow "B"
in the safety information, page 19. If you
don't smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise
Press in control knob for five (5) seconds
(see Figure 32).
Note: You may be running this heater for
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 21.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob coun-
terclockwise
10. Wait one minute and switch selector
switch to the ON position to light burner.
Control Knob
Flame Adjustment
Knob
Figure 32 - Control Knob and Ignitor
Button Location (Shown as Supplied, No
Control Options)
20
OPERATION
Continued
to the PILOT position.
to the ON position.
Ignitor Button
AUTO
OFF
ON
Selector Switch
www.fmiproducts.com
11. Set flame adjustment knob to any level
between HI and LO.
12. To leave pilot lit and shut off burners only:
turn control knob clockwise
PILOT position, or use remote control
manual OFF button, or set selector switch
in the OFF position.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: Make sure the
selector switch is in the OFF
position when you are away from
home for long periods of time.
Fireplace will come on automati-
cally with selector switch in the
ON position.
Pilot Burner
Figure 33 - Pilot (Propane/LP)
Pilot Burner
Figure 34 - Pilot (Natural)
TO TURN OFF GAS
TO AppLIANCE
1. Turn control knob clockwise
OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote: Set
selector switch in the OFF position to keep
from draining the battery.
3. Close equipment shutoff valve (see Fig-
ure 21, page 16).
to the
Ignitor
Electrode
Ignitor
Electrode
to the
113109-01H