Remove the screw securing the Systems Insight Display, and then remove the Systems Insight
8.
Display.
To replace the component, reverse the removal procedure.
Removing an expansion slot blank
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some
internal circuitry remain active until AC power is removed.
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components,
minimize the amount of time the access panel is open.
To remove the component:
Power down the server (on page 27).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 27).
o
Remove the server from the rack (on page 28).
o
Remove the access panel
4.
Remove the PCIe riser cage:
5.
Primary PCIe riser cage (on page 34)
o
Secondary PCIe riser cage (on page 35)
o
Remove the expansion slot blank:
6.
("Access
panel" on page 32).
Removal and replacement procedures 54