SERVICE MANUAL
Model: BD-181SAA, BD-271SAA

8-2. Main parts parameter

Part Name
Check Method and Criterion
Measure the resistance with a tester.
(Ambient temperature : Room temperature 25°C)
Model
Compressor
Embraco
EMX40CLC
Measure the resistance with a tester.
(Ambient temperature : Room temperature 25°C)
Model
Starter
Normal
Abnormal
Measure the resistance with a tester.
(Ambient temperature : Room temperature 25°C)
Overload
Model
Protector
Normal
Abnormal
Measure the resistance with a tester.
(Ambient temperature : Room temperature 25°C)
Running
Model
Capacitor
Normal
Abnormal
Main Wiring
Normal
27.25Ω
Abnormal
Open(∞Ω) or Short Circuited (0 Ω)
Open(∞Ω) or Short Circuited (0Ω)
4TM189KFBYY-53 or BT53-105A61D3
Open(∞Ω) or Short Circuited (0Ω)
4.0±5% µF / 450 VAC
Short Circuited (0Ω)
Issue 2011-2-10
Rev.
Auxiliary Wiring
22.40 Ω
TSD
30 Ω± 20%
Less than 1 Ω
Open(∞Ω)
Ref1102S001V0
18