Oreck UK30200 User Manual page 19

Hide thumbs Also See for UK30200:
Table of Contents

Advertisement

Available languages

Available languages

CONTACT OUR CUSTOMER CARE LINE
1-800-989-3535 (Mon-Fri 7 a.m. – 7 p.m. CST; Sat 8 a.m. – 4:30 p.m. CST)
4
Twist lower tube connector
counterclockwise and slide up. Pull
the lower tube out of the fan housing.
Once removed, check for blockage.
LUBRICATION
The motor and brushroll are equipped with bearings which contain sufficient lubrication for their
lifetime. The addition of lubricant could cause damage. Do not add lubricant to motor or brushroll.
5
If the lower tube is not blocked, look
into the fan housing for blockage. Be
sure to reassemble lower tube and
tighten the lower tube connector
before continuing use.
THE BELT
This vacuum is equipped with the Endurolife
Belt, which is designed for long life and doesn't
need changing.
MOTOR PROTECTION
If the vacuum becomes overloaded (which could
occur when a large obstruction is sucked up
or when vacuuming extremely thick carpet),
the electronics are designed to shut down
the vacuum. If this happens, the vacuum will
automatically shut off and the headlights will
flash. To reset the vacuum, turn the unit "off",
then turn on to continue use. If it shuts down
again there may be a large obstruction in the
vacuum. See Clearing Blockages for the steps on
clearing a blockage.
WARNING
TO REDUCE THE RISK OF
PERSONAL INJURY, UNPLUG BEFORE CLEANING
OR SERVICING.
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uk30300

Table of Contents