Dyna-Glo RMC-FA300DGD Operating Instructions & Parts Manual

Dyna-Glo RMC-FA300DGD Operating Instructions & Parts Manual

Delux propane construction heater

Advertisement

Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for
future reference.
Dyna-Glo
Propane Construction Heater
Description
Dyna-Glo
Delux Model RMC-FA300DGD heaters are 300,000 BTU/Hr construction
TM
heaters. This heater uses propane gas for combustion, and electricity to run the
fan. It is primarily intended for temporary heating of well-ventilated buildings
under construction, alteration or repair. This heater should be utilized in sheltered,
well-ventilated areas, but never in occupied dwellings.

Specifications

Electrical Specifications

Model
Electrical Input
120 V, 60 Hz

General Specifications

Output Rating
Model
BTU/Hr
RMC-FA300DGD
300,000
Hot Air Output
Model
Approx. (CFM) Motor
FA300DGD
RMC-FA300DGD
1800

Table of Contents

Description . . . . . . . . . . . . . . . . . . . . . . .1
Specifications. . . . . . . . . . . . . . . . . . . . . .1
Unpacking . . . . . . . . . . . . . . . . . . . . . . . 1

General Safety Information . . . . . . . . 1-3

Theory of Operation. . . . . . . . . . . . . . . .3
Installation. . . . . . . . . . . . . . . . . . . . . . 3-4
Ventilation. . . . . . . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . . . . . 4-5
Maintenance . . . . . . . . . . . . . . . . . . . . 5-6
Storage . . . . . . . . . . . . . . . . . . . . . . . . . .6
Wiring Diagram. . . . . . . . . . . . . . . . . . . .6
Repair Parts Illustration
and Parts List . . . . . . . . . . . . . . . . . . . . 7-8
Troubleshooting Chart . . . . . . . . . . . . . .9
Warranty . . . . . . . . . . . . . . . . . . . . . . . .11
Unpacking
1. Unpack all materials used to protect
the heater inside of carton. Retain
plastic caps attached to exposed
fittings for use during storage.
www.ghpgroupinc.com
Delux
TM
Amperage
0.65
ANS Z83.7-2011 CSA 2.14-2011 Construction Heater
Fuel
Propane Vapor Only
Minimum Supply
Pressure to Regulator
0.085 HP
25 PSIG (For purposes
1,720 RPM
of input adjustment)
Page
2. Remove heater, accessories and all
hardware from carton.
3. Inspect all items for damage that may
have occurred during shipment.
WARNING
COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS
HEATER, CAN RESULT IN DEATH, SERIOUS
BODILY INJURY AND PROPERTY LOSS,
OR DAMAGE FROM THE HZARARDS OF
FIRE, EXPLOSION, BURN. ASPHYXIATION,
CARBON MONOXIDE POISONING, AND/
OR ELECTRIC SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND
AND FOLLOW THE INSTRUCTIONS
SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER
INFORMATION SUCH AS AN INSTRUCTION
MANUAL, LABELS, ETCETERA, CONTACT
THE MANUFACTURER.
General Safety Information
IMPORTANT: Be sure to read and
understand all cautions and warnings,
Printed in China
C
US
Maximum Fuel
Consumption
Ignition
13.9 lb/h
Direct Spark, Interrupted
(6.3 kg/h)
Maximum Supply
Pressure to Regulator
Max Bottle Pressure
GENERAL HAZARD
WARNING
FAILURE TO
RMC-FA300DGD
Figure 1 - Model RMC-FA300DGD
Regulator
Outlet Pressure
7-10 PSIG
Size
L x W x H (Inches)
RMC-RMC-
33.7 x 12.6 x 18.5
(85.6 x 32 x 47 cm)
before operating this heater. Keep
this instruction manual for future
reference, and use it as a guide to safe
and proper operation of the heater.
Various precautions appear throughout
this manual. Please review and pay
close attention to them. Below is an
explanation of the various levels of
caution required while operating this
heater.
Indicates an im minen tly
DANGER
hazardous situation
which, if not avoided, WILL result in death
or serious injury.
Indicates a poten tially
WARNING
hazardous situation
which, if not avoided, COULD result in
death or serious injury.
Indicates a poten tially
CAUTION
hazardous situa tion
which, if not avoided, MAY result in minor
or moderate injury.
FIRE, BURN,
WARNING
INHALATION, AND
EXPLOSION HAZARD, KEEP SOLID
COMBUSTIBLES, SUCH AS BUILDING
IMLPF300DGD - HBC
PROFESSIONAL GRADE

Advertisement

Table of Contents
loading

Summary of Contents for Dyna-Glo RMC-FA300DGD

  • Page 1: Table Of Contents

    Propane Construction Heater Description Dyna-Glo Delux Model RMC-FA300DGD heaters are 300,000 BTU/Hr construction heaters. This heater uses propane gas for combustion, and electricity to run the fan. It is primarily intended for temporary heating of well-ventilated buildings under construction, alteration or repair. This heater should be utilized in sheltered, well-ventilated areas, but never in occupied dwellings.
  • Page 2: Rmc-Fa300Dgd

    RMC-FA300DGD Dyna-Glo Delux Operating Instructions and Parts Manual Dyna-Glo Propane Construction Heater NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! MATERIALS, PAPER OR CARDBOARD, A SAFE specific applications. or other flammable items on the heater. DISTANCE AWAY FROM THE HEATER AS Your local authority can advise you •...
  • Page 3: Theory Of Operation

    Dyna-Glo Delux Operating Instructions and Parts Manual Models RMC-FA300DGD NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! • Gas supply connections should be Motor and fan must be SAFETY CONTROL SYSTEM WARNING checked using a 50/50 solution of liquid running before lighting,...
  • Page 4: Ventilation

    RMC-FA300PF/DG/DGD ProFitter & Dyna-Glo Operating Instructions and Parts Manual RMC-FA300DGD Dyna-Glo Delux Operating Instructions and Parts Manual ProFitter Dyna-Glo & Dyna-Glo Propane Construction Heater NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Installation Operation Installation Operation Review and under- Review and under-...
  • Page 5: Operation

    Dyna-Glo Delux Operating Instructions and Parts Manual Model RMC-FA300DGD NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Operation (Continued) Maintenance Do not adjust the Do not attempt to IMPORTANT: Always remove the fan regulator above 10 service the heater from the motor shaft before removing...
  • Page 6: Storage

    RMC-FA300PF/DG/DGD RMC-FA300DGD ProFitter Dyna-Glo & Dyna-Glo Delux Operating Instructions and Parts Manual Operating Instructions and Parts Manual Dyna-Glo ProFitter & Dyna-Glo Propane Construction Heater NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Maintenance (Continued) IGNITOR 2. Replace the plastic caps over the...
  • Page 7 RMC-FA300PF/DG/DGD Dyna-Glo Delux Operating Instructions and Parts Manual RMC-FA300DGD ProFitter & Dyna-Glo Operating Instructions and Parts Manual For Repair Parts, call 1-877-447-4768 24 hours a day – 365 days a year Please provide following information: -Model number -Serial number (if any)
  • Page 8 RMC-FA300DGD Dyna-Glo Delux Operating Instructions and Parts Manual Model RMC-FA300DGD Use only original WARNING replacement parts. This Heater must use design- specific parts. Do not substitute or use NEVER LEAVE THE HEATER generic parts. Improper replacement parts could cause serious or fatal injuries.
  • Page 9: Troubleshooting Chart

    RMC-FA300DGD RMC-FA300PF/DG/DGD Dyna-Glo Delux Operating Instructions and Parts Manual ProFitter & Dyna-Glo Operating Instructions and Parts Manual Dyna-Glo ProFitter & Dyna-Glo Propane Construction Heater Troubleshooting Chart Symptom Possible Cause(s) Corrective Action NEVER LEAVE THE HEATER Fan does not turn when 1.
  • Page 11 RMC-FA300DGD Dyna-Glo Delux Operating Instructions and Parts Manual LIMITED WARRANTY: This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group, Inc., within one (1) year of retail purchase.
  • Page 12: Warranty Registration

    WARRANTY REGISTRATION IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records.

Table of Contents