Samsung DV9*K60 series User Manual page 20

Heat pump dryer
Table of Contents

Advertisement

Installation
20
English
DV6000K_DC68-03709C_EN (U.K ).indd 20
3. Connect accessory hose (long drain
hose) to the hole next to the hole that
is connected to drain hose (B).
CAUTION
Because the dryer's drain pump can
only pump up the drain water to a 90
B
cm height, when you connect the drain
hose (B) to the drain point, make sure
that the height of drain point does not
exceed 90 cm.
A drainage check may occur if the
drain point exceeds 90 cm. If a
drainage check occurs, the control
panel displays an check code.
After connecting the drain hose, you
can directly drain the condensed
water via the drain-outlet through the
connected drain hose or through the
washstand or the drain-outlet of the
washstand.