Proper Chimney
Termination?
(Check 1)
Chimney channel
free of solid and
liquid fuel
appliances?
(Check 2)
Crown in good
condition
(Check 3)
Cleanout free of
debris?
(Check 4)
Liner in good
condition?
(Check 5)
Dilution air
available?
(Check 6)
Complete the
installation.
(Check 7)
C
1 - P
HECK
ROPER CHIMNEY TERMINATION
A masonry chimney used as a vent for gas fired equipment must
extend at least three feet above the highest point where it passes
through the roof. It must extend at least two feet higher than any
portion of a building within a horizontal distance of 10 feet. In
addition, the chimney must terminate at least 3 feet above any
forced air inlet located within 10 feet. The chimney must extend at
least five feet above the highest connected equipment draft hood
outlet or flue collar.
Change venting
arrangements
(Fix 2)
Rebuild crown
(Fix 3)
and/or Reline
(Fix 4)
Reline
(Fix 4)
Reline
(Fix 4)
Reline
(Fix 4)
.
11
If the chimney does not meet these termination requirements, but
all other requirements in the checklist can be met, it may be pos-
sible for a mason to extend the chimney. If this will not be practi-
cal, see Fix 1.
10' or Less
2' Min.
Termination 10 Feet Or Less From Ridge, Wall or Parapet
More than 10'
NOTE: No Height
above parapet
required when distance
Wall or
from walls or parapet is
Parapet
more than 10 feet.
More than 10'
Ridge
Termination More Than 10 Feet From Ridge, Wall or Parapet
C
2 - A
HECK
NY SOLID OR LIQUID FUEL APPLIANCES VENTED INTO THIS
CHIMNEY CHANNEL
Solid fuel appliances include fireplaces, wood stoves, coal fur-
naces, and incinerators.
Liquid fuel appliances include oil furnaces, oil-fired boilers and
oil-fired water heaters.
2' Min.
3' Min.
Wall or
Parapet
Chimney
10' or Less
2' Min.
3' Min.
Chimney
3' Min.
Chimney
Height above any
roof surface within
10 feet horizontally.
10'
2" Min.
3' Min.
Chimney