Amana M8 Installation Instructions Manual page 36

Table of Contents

Advertisement

T
ROUBLESHOOTING
Symptoms of
Abnormal Operation
•Furnace not operating.
•Integrated control
module diagnostic LED is
flashing EIGHT (8) flashes.
•Induced draft blower runs
continuously. No furnace
operation.
•Integrated control module
diagnostic LED is flashing
continuously.
•LED is steady on
2
LED Flash code will cease if power to the control module is interrupted through the disconnect or door switch.
C
HART
Fault
Associated
Associated
Description(s)
LED Code
2
LED Code
2
•Problem with
igniter circuit.
8 FLASHES
•Polarity of 115
C
or 24 volt
power is
reversed.
CONTINUOUS
FLASHING
• Normal operation.
STEADY
PCBBF134 & PCBBF132 CONTROL BOARDS
Possible Causes
•Improperly connected
igniter.
•Bad igniter.
•Poor unit ground.
•Poor burner ground.
•Faulty integrated control
module.
•Polarity of 115 volt AC
power to furnace or
integrated control module
is reversed.
•Red and blue wires to
transformer are reversed.
•Poor unit ground.
36
Corrective Action
•Check and correct wiring
•Turn power OFF
from integrated control
module to igniter.
• Compare igniter
•Replace igniter
resistance to spec.
Replace if necessary.
•Read precautions
• Check and correct unit
ground wiring.
•Replace bad integrated
control module.
•Review wiring diagram to
•Turn power OFF
correct polarity.
•Verify proper ground.
Correct if necessary.
•Reverse red and blue wires
connected to transformer.
Cautions
& Notes
prior to repair.
with proper
replacement part.
in "Electrostatic
Discharge" section
of manual.
prior to repair.