INITIAL SETUP PROCEDURE

INITIAL SETTINGS

Sim 21-01
Maintenance Cycle Setting
ARM550U set 250k
ARM620U set 300k
ARM700U set 300k
Sim 26-02
LCC Paper Size Set-up
Sim 26-05
A3 paper count ( set 1or 2 counts)
Sim 26-06
Destination setup
Sim 26-35
Set Multi Error Counter
Set to 1 (Multi Count
IMAGE WRITING DISTORTION (SKEW)
Sim 64-01
Print Area adjust
Pattern 71
Density 100
Level 3
IMAGE POSITION & OFF CENTRE
Sim 50-05
Print Area adjust (Sub scan)
Image Off-Centre adjustment.
Adjust (All Cassettes)
Sim 50-12
OC & RADF Off Centre Adjust
COPY IMAGE POSITION
Sim 50-01
OR
Sim 50-02
Lead/Rear Edge, Image Loss & Void Adjustment
Sim 46-02
Copy Density Adjustment
.
COPY DENSITY
.